Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
4420.0225

4420.0225

Schurter

CIR BRKR THRM MAG 16A 480V 65V

0

4400.0549

4400.0549

Schurter

CIR BRKR THRM 3.3A 240VAC 48VDC

0

4430.1273

4430.1273

Schurter

CIR BRKR THRM 1A 240VAC 60VDC

209

TS-709-8

TS-709-8

Schurter

CIR BRKR THRM 8A 250VAC 50VDC

226

4430.2014

4430.2014

Schurter

CIR BRKR THRM 16A 240VAC 60VDC

14

4410.9012

4410.9012

Schurter

CIR BRKR THRM 16A 240VAC 28VDC

28

4435.0267

4435.0267

Schurter

CIR BRKR THRM 5A 240VAC 60VDC

0

4411.0073

4411.0073

Schurter

CIR BRKR THRM 25A 277VAC 28VDC

19

4435.0233

4435.0233

Schurter

CIR BRKR THRM 6A 240VAC ROCKER

14

4435.0571

4435.0571

Schurter

CIR BRKR THRM 3A 240VAC 32VDC

56

4435.0103

4435.0103

Schurter

CIR BRKR THRM 5A 240VAC 32VDC

9

4430.1855

4430.1855

Schurter

CIR BRKR THRM 8.5A 240VAC 60VDC

11

4430.2196

4430.2196

Schurter

CIR BRKR THRM 20A 240VAC 60VDC

231300

4435.0625

4435.0625

Schurter

CIR BRKR THRM 4A 240VAC 32VDC

19

4404.0059

4404.0059

Schurter

CIR BRKR THRM 10A 240VAC 48VDC

0

4400.0735

4400.0735

Schurter

CIR BRKR THRM 50MA 240VAC 48VDC

0

4430.1813

4430.1813

Schurter

CIR BRKR THRM 240VAC 60VDC

0

4430.1365

4430.1365

Schurter

CIR BRKR THRM 2A 240VAC 60VDC

0

4430.2053

4430.2053

Schurter

CIR BRKR THRM 16A 240VAC 60VDC

0

4430.071

4430.071

Schurter

CIR BRKR THRM 16A 240VAC 60VDC

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure