Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
4435.0358

4435.0358

Schurter

CIR BRKR THRM 5A 240VAC 60VDC

7

4435.0094

4435.0094

Schurter

CIR BRKR THRM 20A 240VAC 60VDC

5

TS-709-15

TS-709-15

Schurter

CIR BRKR THRM 15A 250VAC 50VDC

506

4435.0305

4435.0305

Schurter

CIR BRKR THRM 240VAC 60VDC

10

4435.0036

4435.0036

Schurter

CIR BRKR THRM 7A 240VAC 32VDC

12

4435.0467

4435.0467

Schurter

CIR BRKR THRM 500MA 240VAC 60VDC

5

4411.0013

4411.0013

Schurter

CIR BRKR THRM 2A 277VAC 28VDC

1080

4435.0032

4435.0032

Schurter

CIR BRKR THRM 10A 240VAC 60VDC

19

4435.0262

4435.0262

Schurter

CIR BRKR THRM 10A 240VAC 60VDC

20

4430.2973

4430.2973

Schurter

CIR BRKR THRM 10A 240VAC 60VDC

0

4435.0074

4435.0074

Schurter

CIR BRKR THRM 20A 240VAC 60VDC

17

4430.3295

4430.3295

Schurter

CIR BRKR THRM 240VAC 60VDC

30

4430.3309

4430.3309

Schurter

CIR BRKR THRM 7A 240VAC 60VDC

15

4420.0622

4420.0622

Schurter

CIR BRKR THRM MAG 3A 480V 65V

0

4435.0244

4435.0244

Schurter

CIR BRKR THRM 5A 240VAC 32VDC

9

4435.0239

4435.0239

Schurter

CIR BRKR THRM 4A 240VAC 60VDC

13

4430.2152

4430.2152

Schurter

CIR BRKR THRM 10A 240VAC 60VDC

13

4420.067

4420.067

Schurter

CIR BRKR THRM MAG 16A 480V 65V

0

4435.0185

4435.0185

Schurter

CIR BRKR THRM 20A 240VAC 60VDC

7

4435.0308

4435.0308

Schurter

CIR BRKR THRM 20A 240VAC 60VDC

7

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure