Multiple Conductor Cables

Image Part Number Description / PDF Quantity Rfq
30-00535

30-00535

Tensility International Corporation

CABLE 10COND 28AWG WHT 1=153M

0

30-01484

30-01484

Tensility International Corporation

CBL 7COND 20AWG SHLD 153M MPPE

0

30-01303

30-01303

Tensility International Corporation

CBL 7CON 20AWG 153M GRY

0

30-00278

30-00278

Tensility International Corporation

CABLE 3COND 32AWG SHLD 305M

10

30-01173

30-01173

Tensility International Corporation

CBL 8CON 28AWG SHLD GRY BIO 153M

0

30-01288

30-01288

Tensility International Corporation

CBL 6CON 18AWG 153M GRY

0

30-00808

30-00808

Tensility International Corporation

CBL 2CON 300V 28AWG BLK 153M

41

31-00084

31-00084

Tensility International Corporation

CBL COIL SHLD 6C 26AWG 1115MM

0

30-00923

30-00923

Tensility International Corporation

CBL 24AWG TPU SHLD 5CON 153M

0

31-00037

31-00037

Tensility International Corporation

CBL COIL SHLD 4C 18AWG 2230MM

0

30-00942

30-00942

Tensility International Corporation

CBL 22AWG TPU SHLD 9CON 153M

0

30-01203

30-01203

Tensility International Corporation

CBL 10CON 28AWG SHLD GRY 153M

0

30-01028

30-01028

Tensility International Corporation

CBL 4CON 20AWG SHLD WHT 153M

0

30-01020

30-01020

Tensility International Corporation

CBL 3CON 24AWG SHLD WHT 153M

0

30-01296

30-01296

Tensility International Corporation

CBL 6CON 26AWG 153M WHT

0

30-01448

30-01448

Tensility International Corporation

CBL 4COND 32AWG SHLD 153M MPPE

8

30-00803

30-00803

Tensility International Corporation

CABLE 2COND 24AWG WHITE 153M

0

30-01031

30-01031

Tensility International Corporation

CBL 4CON 24AWG SHLD BLK 153M

14

30-00520

30-00520

Tensility International Corporation

CABLE 8COND 24AWG WHT 1=153M

0

30-01478

30-01478

Tensility International Corporation

CBL 6COND 30AWG SHLD 153M MPPE

0

Multiple Conductor Cables

1. Overview

Multiple Conductor Cables (MCC) are composite cable structures containing two or more individually insulated conductors enclosed within a common jacket. These cables enable simultaneous transmission of power, data, and control signals in complex systems. Their modular design optimizes space utilization while maintaining signal integrity, making them essential in industrial automation, telecommunications, and energy distribution systems.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Control CablesLow capacitance, high flexibility, 300-1000V ratingPLC systems, factory automation
Power CablesLarge cross-section conductors, thermal-resistant insulationMachinery power supply, HVAC systems
Data Communication CablesTwisted pair configurations, 100 impedanceEthernet networks, fieldbus systems
Signal CablesShielded designs, noise suppressionSensor networks, instrumentation

3. Structure and Composition

Typical construction includes:

  • Conductors: Annealed copper or aluminum (solid/stranded), 0.14-10mm cross-section
  • Insulation: PVC, XLPE, or FEP materials with 300% elongation
  • Shielding: Aluminum-polyester foil (100% coverage) or braided copper (85% coverage)
  • Jacket: Flame-retardant PVC or LSZH compounds (0.8-3.0mm thickness)

Layered design prevents crosstalk between conductors while maintaining mechanical durability (20N/mm tensile strength).

4. Key Technical Parameters

ParameterTypical RangeSignificance
Conductor Count2-104 conductorsDetermines system integration density
Voltage Rating300V-2000VDefines operational safety margin
Temperature Range-40 C to +125 CEnvironmental adaptability
Shielding Effectiveness60-100dBEMI protection level
Bending Radius7.5 OD to 15 ODInstallation flexibility

5. Application Areas

Primary industries utilizing MCC:

  • Industrial Automation: Robotic arms, CNC machines
  • Transportation: Rail vehicle control systems
  • Energy: Wind turbine pitch control systems
  • Telecommunications: 5G base station interconnects

Case Study: Automotive production lines use 24-conductor control cables to synchronize robotic welding stations with <0.1ms latency.

6. Leading Manufacturers

ManufacturerKey ProductsSpecialization
LegrandOkonite Multi-ConductorBuilding automation solutions
Belden8760 DataTuffIndustrial Ethernet cables
Prysmian GroupFire resistant Ecos ZEnergy sector applications
Alpha Wire3279 UltraFlexHigh-flex robotics cables

7. Selection Guidelines

Key considerations:

  • Current carrying capacity vs. conductor size (I = 3.2 Amm for Cu)
  • Chemical resistance requirements (oil/grease exposure)
  • Signal transmission requirements (CAT5e/CAT6 data rate support)
  • Regulatory compliance (UL/CSA/IEC standards)
  • Mechanical stress factors (vibration, bending cycles)

Recommend conducting thermal cycling tests (-20 C to +85 C) for critical applications.

8. Industry Trends

Emerging developments include:

  • Hybrid cables integrating fiber optics and power conductors
  • Nano-coated conductors for 50% weight reduction
  • Smart cables with embedded temperature/sensor monitoring
  • Halogen-free materials meeting IEC 60754-1 standards
  • Miniaturization trend: 0.08mm micro-conductors in medical cables

Market forecasts indicate 6.2% CAGR through 2030 driven by Industry 4.0 adoption.

RFQ BOM Call Skype Email
Top