Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
G3X1LG6

G3X1LG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

35198

G6X4BL6

G6X4BL6

Panduit Corporation

SLOTTED DUCT, PVC,6"X4"X6',BLACK

106

NNC100X75LG2

NNC100X75LG2

Panduit Corporation

WIRE DUCT SLOTTED 2PC SCRW 6.56'

6

NE2X2WH6-A

NE2X2WH6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW WT 6'

201974

H3X3BL6

H3X3BL6

Panduit Corporation

WIRE DUCT SLOTTED SCREW BLACK 6'

8

T70BIW6

T70BIW6

Panduit Corporation

WIRE DUCT SOLID BASE SCRW WHT 6'

5952

G6X4WH6

G6X4WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

34

NNC25X37LG2

NNC25X37LG2

Panduit Corporation

WIRE DUCT SLOTTED 2PC SCRW 6.56'

7180

D1.5X3WH6

D1.5X3WH6

Panduit Corporation

WIRE DUCT ROUND SCREW WHITE 6'

19

HS4X4BL6NM

HS4X4BL6NM

Panduit Corporation

WIRE DUCT SOLID BASE BLACK 6'

10

PC-658L

PC-658L

Panduit Corporation

5.437X3.062X72.688 MC/CARR 6 FT

0

MC50X100WH2

MC50X100WH2

Panduit Corporation

WIRE DUCT SLOTTED 2PC SCRW 6.56'

4

D1X4BL6

D1X4BL6

Panduit Corporation

WIRE DUCT ROUND SCREW BLACK 6'

1278

T70BWH10

T70BWH10

Panduit Corporation

WIRE DUCT SOLID BASE SCREW 10'

1320

HS1.5X2LG6NM

HS1.5X2LG6NM

Panduit Corporation

WIRE DUCT SOLID BASE GRAY 6'

12

MC25X75IG2

MC25X75IG2

Panduit Corporation

WIRE DUCT SLOTTED 2PC SCRW 6.56'

14

G6X4LG6

G6X4LG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

51890

NNC25X25WH2

NNC25X25WH2

Panduit Corporation

WIRE DUCT SLOTTED 2PC SCRW 6.56'

0

NE4X4WH6-A

NE4X4WH6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW WT 6'

0

HS2X2WH6NM

HS2X2WH6NM

Panduit Corporation

WIRE DUCT SOLID BASE WHITE 6'

38

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers

RFQ BOM Call Skype Email
Top