Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
G2X3WH6-A

G2X3WH6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW WT 6'

10114

NNC50X50WH2

NNC50X50WH2

Panduit Corporation

WIRE DUCT SLOTTED 2PC SCRW 6.56'

2060

MC37X37IG2

MC37X37IG2

Panduit Corporation

WIRE DUCT SLOTTED 2PC SCRW 6.56'

26

G4X3WH6

G4X3WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

39

MC62X62IG2

MC62X62IG2

Panduit Corporation

WIRE DUCT SLOTTED 2PC SCRW 6.56'

15240

G3X5LG6

G3X5LG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

563570

G3X4BL6

G3X4BL6

Panduit Corporation

WIRE DUCT SLOTTED SCREW BLACK 6'

106

G2X4IB6

G2X4IB6

Panduit Corporation

WIRE DUCT SLOTTED SCREW BLUE 6'

30984

NNC37X50LG2

NNC37X50LG2

Panduit Corporation

WIRE DUCT SLOTTED 2PC SCRW 6.56'

1920

PC-565/2M

PC-565/2M

Panduit Corporation

CTN 4.937X2.437X79.375 WS-0230 D

0

G4X2WH6

G4X2WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

17

G3X2LG6-A

G3X2LG6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW GY 6'

1278

MC25X62WH2

MC25X62WH2

Panduit Corporation

WIRE DUCT SLOTTED 2PC SCRW 6.56'

0

HN2X2LG6

HN2X2LG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

12144

DRD44WH6

DRD44WH6

Panduit Corporation

WIRE DUCT SLOTTED DIN RL FAST 6'

4810

PC-771L

PC-771L

Panduit Corporation

CARTON 3.715X2.179X79.752

0

G3X3WH6-A

G3X3WH6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW WT 6'

10

G1X2IB6

G1X2IB6

Panduit Corporation

WIRE DUCT SLOTTED SCREW BLUE 6'

596

NE3X2WH6

NE3X2WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

38348

T45BWH8

T45BWH8

Panduit Corporation

PWR RATED MULTICHAN RACEWAY B 8'

0

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers

RFQ BOM Call Skype Email
Top