Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
184-13006

184-13006

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

MCRFW-B10

MCRFW-B10

HellermannTyton

WIRE DUCT SOLID MULTI SCREW 10'

0

181-00203

181-00203

HellermannTyton

WIRE DUCT SOLID BASE SCRW WHT 6'

0

184-43002

184-43002

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

181-13004

181-13004

HellermannTyton

WIRE DUCT SLOTTED SCREW BLUE 6'

0

181-00616

181-00616

HellermannTyton

WIRE DUCT SLOTTED SCREW BLACK 6'

19

184-22029

184-22029

HellermannTyton

SLHD2X5 BLACK PVC DUCT

0

181-23092

181-23092

HellermannTyton

SLOTTED-WALL WIRING DUCT, 2.5" X

20

181-33012

181-33012

HellermannTyton

WIRE DUCT SLOTTED SCREW BLUE 6'

0

184-22025

184-22025

HellermannTyton

SLHD2X3 BLACK PVC DUCT

0

181-00198

181-00198

HellermannTyton

WIRE DUCT SOLID BASE SCRW WHT 6'

0

184-23005

184-23005

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

184-22026

184-22026

HellermannTyton

WIRE DUCT SLOTTED SCREW BLUE 6'

0

184-15300

184-15300

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

184-33003

184-33003

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

181-32014

181-32014

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW WT 6'

0

181-00686

181-00686

HellermannTyton

WIRE DUCT SLOTTED SCREW BLUE 6'

0

TSRP1FW-6A

TSRP1FW-6A

HellermannTyton

WIRE DUCT SOLID ADH SCREW WHT 6'

0

181-15208

181-15208

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

184-15200

184-15200

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers