Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
181-24010

181-24010

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

184-34004

184-34004

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

181-31006

181-31006

HellermannTyton

SL3X1 WHITE PVC DUCT

120

181-00321

181-00321

HellermannTyton

SLHD2X5 W/ADH BLACK PVC DUCT

0

181-15512

181-15512

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW GY 6'

0

181-00231

181-00231

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW GY 6'

0

184-11002

184-11002

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW WT 6'

0

181-75750

181-75750

HellermannTyton

WIRE DUCT SOLID BASE SCRW GRY 6'

0

181-15212

181-15212

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW WT 6'

0

181-00242

181-00242

HellermannTyton

SL2X5 W/ADH WHITE PVC DUCT

0

184-21001

184-21001

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW GY 6'

0

181-15200

181-15200

HellermannTyton

WIRE DUCT SOLID BASE SCRW GRY 6'

0

181-24005

181-24005

HellermannTyton

SLOTTED WALL WIRING DUCT, 2" X 4

19

181-00666

181-00666

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW BK 6'

0

181-00172

181-00172

HellermannTyton

WIRE DUCT SOLID BASE SCRW GRY 6'

0

181-00618

181-00618

HellermannTyton

WIRE DUCT SLOTTED SCREW BLACK 6'

0

181-00456

181-00456

HellermannTyton

WIRE DUCT SOLID BASE SCRW WHT 6'

0

181-00475

181-00475

HellermannTyton

WIRE DUCT SOLID BASE SCRW WHT 6'

0

181-00233

181-00233

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

181-33019

181-33019

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW BK 6'

0

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers