Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
FS.5X.5LG6

FS.5X.5LG6

Panduit Corporation

WIRE DUCT SOLID BASE SCRW GRY 6'

15

G3X3BL6

G3X3BL6

Panduit Corporation

WIRE DUCT SLOTTED SCREW BLACK 6'

663162

FS2X1LG6NM

FS2X1LG6NM

Panduit Corporation

WIRE DUCT SOLID BASE GRAY 6'

14

FS6X4LG6

FS6X4LG6

Panduit Corporation

WIRE DUCT SOLID BASE SCRW GRY 6'

106

LDPH10IG8-A

LDPH10IG8-A

Panduit Corporation

WIRE DUCT SOLID 2PC ADH SCRW 8'

14411360

FS6X4WH6NM

FS6X4WH6NM

Panduit Corporation

WIRE DUCT SOLID BASE WHITE 6'

1054

F2X1.5LG6-A

F2X1.5LG6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW GY 6'

37

3240313

3240313

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

6

FS3X2LG6NM

FS3X2LG6NM

Panduit Corporation

WIRE DUCT SOLID BASE GRAY 6'

8

FS4X4BL6NM

FS4X4BL6NM

Panduit Corporation

WIRE DUCT SOLID BASE BLACK 6'

12342

FWF-10511

FWF-10511

Quest Technology International

RACEWAY ONAROLL 1'' WHT 50 FT

4

181-23007

181-23007

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

2

G2X2WH6

G2X2WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

129384

G1.5X3LG6-A

G1.5X3LG6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW GY 6'

21

FS2X2LG6NM

FS2X2LG6NM

Panduit Corporation

WIRE DUCT SOLID BASE GRAY 6'

1

3240198

3240198

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

3123410

LD10EI8-A

LD10EI8-A

Panduit Corporation

WIRE DUCT SOLID ADHESIVE IVRY 8'

160

1487C36

1487C36

Hammond Manufacturing

WIREWAY PULL THRGH 36" 4X4" GRAY

0

1487B12

1487B12

Hammond Manufacturing

WIREWAY PULL THRGH 12" 2.5X2.5"

0

3240341

3240341

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

13

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers