Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
181-00213

181-00213

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

FWH-12614

FWH-12614

Quest Technology International

WIREHIDER RACEWAY 1'' WHT 6FT 4

741

181-00573

181-00573

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW BK 6'

0

181-15209

181-15209

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

1487C120

1487C120

Hammond Manufacturing

WIREWAY PULL THRGH 120" 4X4" GR

0

AG80100-BOX

AG80100-BOX

Tecnomatic Corp

WIDE FINGER GRAY DUCT 3 X 4 1

3

B25X60S-R

B25X60S-R

Altech Corporation

WIRE DUCT SLOTTED SCREW GRAY 78'

32

MCRI-BS10

MCRI-BS10

HellermannTyton

WIRE DUCT SOLID MULTI SCREW 10'

0

TSR2W-6A

TSR2W-6A

HellermannTyton

WIRE DUCT SOLID ADH SCREW WHT 6'

0

181-43004

181-43004

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

G1X1.5LG6

G1X1.5LG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

5829

1487D12

1487D12

Hammond Manufacturing

WIREWAY PULL THRGH 12" 6X6" GRAY

0

1485D36

1485D36

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 3'

0

FS2X2WH6

FS2X2WH6

Panduit Corporation

WIRE DUCT SOLID BASE SCRW WHT 6'

28

181-43006

181-43006

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

3240189

3240189

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

3191350

F1.5X4LG6-A

F1.5X4LG6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW GY 6'

618

1485B6

1485B6

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTEN 0.50'

0

F1.5X4WH6

F1.5X4WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

515750

MC50X50IG2

MC50X50IG2

Panduit Corporation

WIRE DUCT SLOTTED 2PC SCRW 6.56'

17280

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers

RFQ BOM Call Skype Email
Top