Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
3240354

3240354

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

9420

DRD33LG6

DRD33LG6

Panduit Corporation

WIRE DUCT SLOTTED DIN RL FAST 6'

3192

TSR3FW-6A

TSR3FW-6A

HellermannTyton

WIRE DUCT SOLID ADH SCREW WHT 6'

0

TSRP2W-8A

TSRP2W-8A

HellermannTyton

WIRE DUCT SOLID ADH SCREW WHT 8'

0

LDPH10IW8-A

LDPH10IW8-A

Panduit Corporation

WIRE DUCT SOLID 2PC ADH SCREW 8'

160320

TG70IW8

TG70IW8

Panduit Corporation

PWR RATED MULTICHAN RACEWAY 8'

32736

181-44019

181-44019

HellermannTyton

WIRE DUCT SLOTTED SCREW BLACK 6'

0

3240194

3240194

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

1

181-45010

181-45010

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

G1X1WH6

G1X1WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

465364

F1X3WH6

F1X3WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

4025296

1486B60

1486B60

Hammond Manufacturing

WIRE DUCT SOLID BASE FASTENER 5'

0

3240205

3240205

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

348

LDPH5IW10-A

LDPH5IW10-A

Panduit Corporation

WIRE DUCT SOLID 2PC ADH SCRW 10'

0

3240622

3240622

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

6

3240626

3240626

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

14820

181-00585

181-00585

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW GY 6'

18

1486C48

1486C48

Hammond Manufacturing

WIRE DUCT SOLID BASE FASTENER 4'

0

3240326

3240326

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

0

1485D60

1485D60

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 5'

0

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers

RFQ BOM Call Skype Email
Top