Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
F6X4BL6

F6X4BL6

Panduit Corporation

NARROW SLOT DUCT, PVC, BLACK, 6"

4

1487B60

1487B60

Hammond Manufacturing

WIREWAY PULL THRGH 60" 2.5X2.5"

0

T45BIW10

T45BIW10

Panduit Corporation

WIRE DUCT SOLID BASE SCREW 10'

193200

HN4X4LG6

HN4X4LG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

2

TSRP3FW-6A

TSRP3FW-6A

HellermannTyton

WIRE DUCT SOLID ADH SCREW WHT 6'

0

MC100X50IG2

MC100X50IG2

Panduit Corporation

WIRE DUCT SLOTTED 2PC SCRW 6.56'

3

1485F24

1485F24

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 2'

0

184-12005

184-12005

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

F3X1LG6

F3X1LG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

5

3240350

3240350

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

10

1485E120

1485E120

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 10'

0

G.75X1.5WH6

G.75X1.5WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

3384

F1.5X1.5BL6

F1.5X1.5BL6

Panduit Corporation

NARROW SLOT DUCT, PVC, 1.5" X 1.

18

FWF-14121

FWF-14121

Quest Technology International

RACEWAY ONAROLL 3/8'' BEIGE 100

132

3240192

3240192

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

53400

3240202

3240202

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

10

FWH-12624

FWH-12624

Quest Technology International

WIREHIDER RACEWAY 1'' BEIGE 6FT

60

F2X4WH6-A

F2X4WH6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW WT 6'

1042

FS.75X1.5LG6

FS.75X1.5LG6

Panduit Corporation

WIRE DUCT SOLID BASE SCRW GRY 6'

20168

3240353

3240353

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

5

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers