Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
1487C24

1487C24

Hammond Manufacturing

WIREWAY PULL THRGH 24" 4X4" GRAY

0

G1X2WH6

G1X2WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

411442

3240359

3240359

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

2

3240188

3240188

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

201528

SRWD-1015

SRWD-1015

Richco, Inc. (Essentra Components)

WIRE DUCT SLOTTED 2PC SCRW 6.50'

0

F1X3BL6

F1X3BL6

Panduit Corporation

NARROW SLOTTED DUCT, PVC, 1" X 3

20198

G.5X1LG6

G.5X1LG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

81626

G4X3LG6-A

G4X3LG6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW GY 6'

1036

HS2X2LG6NM

HS2X2LG6NM

Panduit Corporation

WIRE DUCT SOLID BASE GRAY 6'

1

FS.5X.5LG6NM

FS.5X.5LG6NM

Panduit Corporation

WIRE DUCT SOLID BASE GRAY 6'

40

181-00571

181-00571

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW GY 6'

0

F1X2IB6

F1X2IB6

Panduit Corporation

WIRE DUCT SLOTTED SCREW BLUE 6'

43606

G2X1.5LG6-A

G2X1.5LG6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW GY 6'

666

G2X4LG6EMI

G2X4LG6EMI

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

0

184-23004

184-23004

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

FWF-05511

FWF-05511

Quest Technology International

RACEWAY ONAROLL 1/2'' WHT 50 FT

42

3240325

3240325

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

0

G1.5X2LG6-A

G1.5X2LG6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW GY 6'

40

1485D120

1485D120

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 10'

0

181-15403

181-15403

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers