Switching Converter, SMPS Transformers

Image Part Number Description / PDF Quantity Rfq
750314624

750314624

Würth Elektronik Midcom

XFRMR ISOL BUCK DC/DC CONV TH

69

750311624

750311624

Würth Elektronik Midcom

TRANS FLYBACK LT3748 LT3575 9UH

0

749119250

749119250

Würth Elektronik Midcom

WE-POE POWER OVER ETHERNET TRANS

0

750813021

750813021

Würth Elektronik Midcom

OFFLINE XFRM WE-UNIT TI LM3445

0

750811614

750811614

Würth Elektronik Midcom

THT OFFLINE TRANSFORMER WE-UNIT

0

750310020

750310020

Würth Elektronik Midcom

POWER OVER ETHERNET TRANSFORMER

0

750314460

750314460

Würth Elektronik Midcom

TRANSFORMER FLYBACK WE-FB SMD

0

7508110410

7508110410

Würth Elektronik Midcom

OFFLINE TRANSFORMER WE-UNIT

0

750315856

750315856

Würth Elektronik Midcom

ISOLATED BUCK TRANSFORMER

0

750311303

750311303

Würth Elektronik Midcom

TRANS FLYBACK LT3575 50UH SMD

0

750311269

750311269

Würth Elektronik Midcom

TRANSFORMER FLYBACK NCL30001

0

750813530

750813530

Würth Elektronik Midcom

TRANS 3000V SMD

0

750311268

750311268

Würth Elektronik Midcom

FLYBACK XFRM WE-FB BROADCOM

0

750311525

750311525

Würth Elektronik Midcom

TRANS FLYBACK SSL2101 700UH

0

749196108

749196108

Würth Elektronik Midcom

WE-FLEX FLEXIBLE TRANSFORMER FOR

450

760390014

760390014

Würth Elektronik Midcom

TRANSFORMER 475UH SMD

12947

750316018

750316018

Würth Elektronik Midcom

PUSH-PULL TRANSFORMER TOR5.8/3.1

930

749119433

749119433

Würth Elektronik Midcom

TRANS FLYBACK POE+ 42UH SMD

10

750313972

750313972

Würth Elektronik Midcom

TRANS FLYBACK LT8301

0

749196527

749196527

Würth Elektronik Midcom

WE-FLEX FLEXIBLE TRANSFORMER FOR

0

Switching Converter, SMPS Transformers

1. Overview

Switching Mode Power Supply (SMPS) Transformers are critical components in power electronics systems, enabling efficient voltage conversion through high-frequency switching techniques. Unlike traditional linear transformers, SMPS transformers operate at frequencies typically above 20 kHz, allowing reduced size, weight, and improved energy efficiency. These components are essential for modern power management solutions in electronics, renewable energy systems, and industrial automation.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Discontinuous Mode (DCM) FlybackGalvanic isolation, single-switch controlAC-DC adapters, battery chargers
Continuous Mode (CCM) FlybackHigher power density, lower ripple currentLED drivers, industrial power supplies
Forward ConverterEfficient for medium power levels, requires reset circuitServer power supplies, telecom equipment
Push-PullBalanced magnetic utilization, high efficiencyHigh-end audio amplifiers, welding machines
Half-Bridge/Full-BridgeHigh power capability, symmetrical switchingElectric vehicle charging, solar inverters

3. Structure and Components

Typical SMPS transformer construction includes:

  • Core materials: Ferrite (Mn-Zn or Ni-Zn), Powdered Iron, Amorphous alloys
  • Winding configuration: Primary/secondary windings with optimized turn ratios
  • Insulation system: Bobbins, tape insulation, and potting compounds
  • Termination: Tin-plated copper leads or surface-mount pads
  • Shielding: Electrostatic shields for EMI reduction

4. Key Technical Specifications

ParameterImportance
Input Voltage RangeDetermines compatibility with power sources
Output Power RatingDefines maximum energy transfer capability
Switching FrequencyImpacts size, efficiency, and EMI performance
Turns Ratio AccuracyAffects voltage regulation precision
Isolation VoltageEnsures safety and dielectric strength
Efficiency (Typical >90%)Reduces thermal management requirements
Operating TemperatureDetermines reliability in harsh environments

5. Application Fields

Major application sectors include:

  • Consumer Electronics: Mobile device chargers, laptop adapters
  • Industrial: Motor drives, PLC power supplies, test equipment
  • Telecommunications: Base station power systems, optical network equipment
  • Renewable Energy: Solar inverters, energy storage systems
  • Automotive: On-board chargers (OBC), DC-DC converters
  • Medical: Isolated power supplies for diagnostic equipment

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
TDK-LambdaPWM Switching TransformerHigh-density design, 150kHz operating frequency
CoilcraftXEL60xx SeriesUltra-low profile, 25A saturation current
Pulse ElectronicsPA5477NLIntegrated EMI filtering, automotive qualified
Bel/Signal Transformer125-2011-FMedical-grade isolation, 4kV withstand
Delta ElectronicsTMA-101-01High-efficiency (94%), 1kW power rating

7. Selection Guidelines

Key considerations for optimal selection:

  1. Power requirements (continuous vs peak load)
  2. Switching frequency compatibility with controller ICs
  3. Thermal management capabilities
  4. Creepage/clearance distances for safety certification
  5. Cost-performance trade-offs
  6. Package dimensions and mounting requirements
  7. Compliance with standards (UL, IEC, AEC-Q)

8. Industry Trends

Current development directions include:

  • Miniaturization through higher operating frequencies (>1MHz)
  • Integration with wide-bandgap semiconductors (GaN/SiC)
  • Advanced nanocrystalline core materials
  • AEC-Q qualified components for automotive electrification
  • Smart transformers with embedded sensing
  • RoHS-compliant, halogen-free construction

Market forecasts indicate 8.2% CAGR through 2028, driven by 5G infrastructure and renewable energy adoption.

RFQ BOM Call Skype Email
Top