Switching Converter, SMPS Transformers

Image Part Number Description / PDF Quantity Rfq
PA0903NL

PA0903NL

PulseLarsen Antenna

XFMER, 5TP:5TP:4TS:5TPAUX NPB

51

PA5100.006NLT

PA5100.006NLT

PulseLarsen Antenna

TRANSFORMER, FORWARD, EP7 PLUS,

0

PA3856.006NLT

PA3856.006NLT

PulseLarsen Antenna

TRANSFORMER FORWARD 128UH SMD

0

PA5131.004NLT

PA5131.004NLT

PulseLarsen Antenna

TRANSFORMER, FORWARD, EP10 PLUS,

123

PH0801CNLT

PH0801CNLT

PulseLarsen Antenna

XFMR, ER19 PLANAR, 4:4:4, SMT

0

PA3856.005NLT

PA3856.005NLT

PulseLarsen Antenna

TRANSFORMER FORWARD 128UH SMD

0

PH0812CNL

PH0812CNL

PulseLarsen Antenna

XFMR DC/DC CONV SMD

0

PA3855.003NLT

PA3855.003NLT

PulseLarsen Antenna

TRANSFORMER FLYBACK 41UH SMD

630

PA3856.004NL

PA3856.004NL

PulseLarsen Antenna

XFMR,FORWARD,EEP13,SMT NPB

2682

PA0808NL

PA0808NL

PulseLarsen Antenna

XFMR DC/DC CONV SMD

0

PH0807CNLT

PH0807CNLT

PulseLarsen Antenna

XFMR, ER19 PLANAR, 4:5:1:1, SMT

0

PA5100.002NLT

PA5100.002NLT

PulseLarsen Antenna

TRANSFORMER, FORWARD, EP7 PLUS,

125

PA3856.004NLT

PA3856.004NLT

PulseLarsen Antenna

TRANSFORMER FORWARD 128UH SMD

0

PA5131.005NLT

PA5131.005NLT

PulseLarsen Antenna

TRANSFORMER, FORWARD, EP10 PLUS,

123

PA3855.004NLT

PA3855.004NLT

PulseLarsen Antenna

TRANSFORMER FLYBACK 21UH SMD

0

PA3855.006NLT

PA3855.006NLT

PulseLarsen Antenna

TRANSFORMER FLYBACK 21UH SMD

2617

PA2369NL

PA2369NL

PulseLarsen Antenna

TRANSFORMER SWITCH MODE 5A

1617

PH0802CNLT

PH0802CNLT

PulseLarsen Antenna

XFMR, ER19 PLANAR, 4:5:2:2, SMT

0

PH0809CNLT

PH0809CNLT

PulseLarsen Antenna

XFMR, ER19 PLANAR, 5:6:1:1 SMT

0

PH0814CNLT

PH0814CNLT

PulseLarsen Antenna

XFMR, ER19 PLANAR, 5:6:2:1, SMT

0

Switching Converter, SMPS Transformers

1. Overview

Switching Mode Power Supply (SMPS) Transformers are critical components in power electronics systems, enabling efficient voltage conversion through high-frequency switching techniques. Unlike traditional linear transformers, SMPS transformers operate at frequencies typically above 20 kHz, allowing reduced size, weight, and improved energy efficiency. These components are essential for modern power management solutions in electronics, renewable energy systems, and industrial automation.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Discontinuous Mode (DCM) FlybackGalvanic isolation, single-switch controlAC-DC adapters, battery chargers
Continuous Mode (CCM) FlybackHigher power density, lower ripple currentLED drivers, industrial power supplies
Forward ConverterEfficient for medium power levels, requires reset circuitServer power supplies, telecom equipment
Push-PullBalanced magnetic utilization, high efficiencyHigh-end audio amplifiers, welding machines
Half-Bridge/Full-BridgeHigh power capability, symmetrical switchingElectric vehicle charging, solar inverters

3. Structure and Components

Typical SMPS transformer construction includes:

  • Core materials: Ferrite (Mn-Zn or Ni-Zn), Powdered Iron, Amorphous alloys
  • Winding configuration: Primary/secondary windings with optimized turn ratios
  • Insulation system: Bobbins, tape insulation, and potting compounds
  • Termination: Tin-plated copper leads or surface-mount pads
  • Shielding: Electrostatic shields for EMI reduction

4. Key Technical Specifications

ParameterImportance
Input Voltage RangeDetermines compatibility with power sources
Output Power RatingDefines maximum energy transfer capability
Switching FrequencyImpacts size, efficiency, and EMI performance
Turns Ratio AccuracyAffects voltage regulation precision
Isolation VoltageEnsures safety and dielectric strength
Efficiency (Typical >90%)Reduces thermal management requirements
Operating TemperatureDetermines reliability in harsh environments

5. Application Fields

Major application sectors include:

  • Consumer Electronics: Mobile device chargers, laptop adapters
  • Industrial: Motor drives, PLC power supplies, test equipment
  • Telecommunications: Base station power systems, optical network equipment
  • Renewable Energy: Solar inverters, energy storage systems
  • Automotive: On-board chargers (OBC), DC-DC converters
  • Medical: Isolated power supplies for diagnostic equipment

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
TDK-LambdaPWM Switching TransformerHigh-density design, 150kHz operating frequency
CoilcraftXEL60xx SeriesUltra-low profile, 25A saturation current
Pulse ElectronicsPA5477NLIntegrated EMI filtering, automotive qualified
Bel/Signal Transformer125-2011-FMedical-grade isolation, 4kV withstand
Delta ElectronicsTMA-101-01High-efficiency (94%), 1kW power rating

7. Selection Guidelines

Key considerations for optimal selection:

  1. Power requirements (continuous vs peak load)
  2. Switching frequency compatibility with controller ICs
  3. Thermal management capabilities
  4. Creepage/clearance distances for safety certification
  5. Cost-performance trade-offs
  6. Package dimensions and mounting requirements
  7. Compliance with standards (UL, IEC, AEC-Q)

8. Industry Trends

Current development directions include:

  • Miniaturization through higher operating frequencies (>1MHz)
  • Integration with wide-bandgap semiconductors (GaN/SiC)
  • Advanced nanocrystalline core materials
  • AEC-Q qualified components for automotive electrification
  • Smart transformers with embedded sensing
  • RoHS-compliant, halogen-free construction

Market forecasts indicate 8.2% CAGR through 2028, driven by 5G infrastructure and renewable energy adoption.