Specialty Transformers

Image Part Number Description / PDF Quantity Rfq
PH9384.021NLT

PH9384.021NLT

PulseLarsen Antenna

XFMR GATE-DR 2CT:1CT SM NPB

569

PH9385.015NLT

PH9385.015NLT

PulseLarsen Antenna

XFMR PUSH-PULL SIDE CAR 1:5 SMT

0

PH9085.011NLT

PH9085.011NLT

PulseLarsen Antenna

IND PWR 3.0X3.0X1.2 1.02MH SMT

0

PE-65812NLT

PE-65812NLT

PulseLarsen Antenna

XFRMR DIGITAL AUDIO 1:1 2.5MH

0

PH9084.021NLT

PH9084.021NLT

PulseLarsen Antenna

XFMR GATE-DR 2CT:1CT SM NPB

1992

PH9384.083NLT

PH9384.083NLT

PulseLarsen Antenna

XFMR GATE-DR 8CT:3CT SM NPB

190

PH9184.021NLT

PH9184.021NLT

PulseLarsen Antenna

XFMR GATE-DR 1CT:2CT SM NPB

797

PG1427.002NLT

PG1427.002NLT

PulseLarsen Antenna

XFMR GATE-DR 1:1:1 SMT NPB

0

PE-68283NL

PE-68283NL

PulseLarsen Antenna

XFRMR DC/DC CONV 9V 80/200MA SMD

0

PE-68283NLT

PE-68283NLT

PulseLarsen Antenna

XFRMR DC/DC CONV 9V 80/200MA SMD

0

PE-64552NL

PE-64552NL

PulseLarsen Antenna

TRANSFORMER

0

PG1427.003NLT

PG1427.003NLT

PulseLarsen Antenna

XFMR GATE-DR 2:1:1 SMT NPB

0

PG1427.004NLT

PG1427.004NLT

PulseLarsen Antenna

XFMR GATE-DR 1:0.7:0.7 NPB

0

PH9085.089NLT

PH9085.089NLT

PulseLarsen Antenna

XFMR GATE-DR 8CT:9CT SM NPB

0

P0585ANL

P0585ANL

PulseLarsen Antenna

4GATE XFMR IEC950 NPB

0

PE-68279NL

PE-68279NL

PulseLarsen Antenna

XFRMR DC/DC CONV 9V 80/200MA SMD

0

PG1427.001NLT

PG1427.001NLT

PulseLarsen Antenna

XFMR GATE-DR 1:1:1 SMT NPB

0

PG1427.003NL

PG1427.003NL

PulseLarsen Antenna

XFMR GATE-DR 2:1:1 SMT NPB

0

PE-6292

PE-6292

PulseLarsen Antenna

TRANSFORMER

3285

PE-68448NL

PE-68448NL

PulseLarsen Antenna

TRANSFORMER GATE DRIVE

0

Specialty Transformers

1. Overview

Specialty Transformers are customized electromagnetic devices designed for specific applications requiring non-standard electrical parameters, isolation requirements, or environmental adaptability. Unlike general-purpose transformers, they are engineered to meet precise technical specifications in voltage conversion, signal isolation, impedance matching, and power conditioning. These transformers play critical roles in advanced power systems, medical equipment, industrial automation, and emerging technologies like renewable energy integration.

2. Major Types and Functional Classification

Type Functional Characteristics Application Examples
Isolation Transformers Provide galvanic isolation with 1:1 turns ratio Medical imaging equipment, industrial safety systems
Auto-transformers Shared winding design for variable voltage adjustment Voltage regulators in power distribution networks
Current Transformers (CTs) Accurate current measurement with stepped-down output Protective relaying in substations, energy meters
Potential Transformers (PTs) Precise voltage scaling for metering and protection Grid monitoring systems, circuit breaker controls
High-Frequency Transformers Operate at 20kHz+ with ferrite cores Switch-mode power supplies, wireless charging systems
Grounding Transformers Create neutral points in ungrounded systems Renewable energy plants, offshore platforms

3. Structure and Components

Typical construction includes:

  • Core: Cold-rolled grain-oriented silicon steel (CRGO) or ferrite materials
  • Windings: Copper/aluminum conductors with epoxy/polyester insulation
  • Insulation System: Combination of paper, varnish, and synthetic resins
  • Housing: Corrosion-resistant steel/aluminum enclosures with IP23-IP54 ratings
  • Cooling System: Air-natural (AN), air-forced (AF), or oil-immersed (ONAN) configurations

4. Key Technical Parameters

Parameter Typical Range Importance
Rated Power (kVA) 0.1-10,000 Determines load capacity and thermal performance
Voltage Ratio 1:1 to 1:100 Defines input/output voltage relationship
Frequency Range (Hz) 50/60, 400, 20k-100k Dictates application suitability
Efficiency (%) 95-99.5 Impacts operational cost and thermal management
Insulation Class A (105 C) to H (155 C) Determines lifespan and safety margins
Short-Circuit Impedance (%) 4-15 Affects fault current limitation and voltage regulation

5. Application Fields

  • Power Systems: Grid substations, HVDC converter stations
  • Industrial: CNC machines, welding robots
  • Telecom: 5G base stations, fiber optic networks
  • Medical: MRI scanners, X-ray machines
  • Transportation: High-speed rail traction systems

6. Leading Manufacturers and Products

Manufacturer Representative Product Key Features
ABB Triton Isolation Transformer Cast-resin design for marine environments
Siemens SITRANS CT Family 0.1% accuracy class for energy metering
GE Grid Solutions TXpert Smart Transformer Integrated IoT sensors for condition monitoring
Schneider Electric Harmonium HF Series 40kHz operation for data center UPS systems
Toshiba H85-GT Grounding Transformer Designed for 132kV renewable energy grids

7. Selection Guidelines

Key considerations:

  • Define exact voltage/current transformation ratio
  • Assess environmental conditions (temperature, humidity, vibration)
  • Verify compliance with standards (IEC 60076, IEEE C57.12)
  • Evaluate cooling requirements and installation space
  • Consider future expansion needs (15-20% capacity margin)

8. Industry Trends

Emerging developments include:

  • Adoption of amorphous metal cores for 80% lower no-load losses
  • Integration of fiber-optic sensors for real-time thermal monitoring
  • Development of planar transformers for EV charging stations
  • Implementation of digital twin technology for predictive maintenance
  • Advancements in nanodielectric insulation materials
RFQ BOM Call Skype Email
Top