Power Transformers

Image Part Number Description / PDF Quantity Rfq
CE2000TH

CE2000TH

SolaHD

PWR XFMR LAMINATED 2000VA CHAS

10

K20E2H45S

K20E2H45S

SolaHD

PWR XFMR LAMINATED CHAS MT

0

CE1500MH

CE1500MH

SolaHD

PWR XFMR LAMINATED 1500VA CHAS

4

E100TH

E100TH

SolaHD

PWR XFMR LAMINATED 100VA CHAS MT

0

HSS10F750B

HSS10F750B

SolaHD

PWR XFMR LAMINATED 750VA CHAS MT

0

E750TF

E750TF

SolaHD

PWR XFMR LAMINATED 750VA CHAS MT

0

HTS5F6AS

HTS5F6AS

SolaHD

PWR XFMR LAMINATED CHAS MT

0

HT7F6AS

HT7F6AS

SolaHD

PWR XFMR LAMINATED CHAS MT

0

HSS14F10BS

HSS14F10BS

SolaHD

PWR XFMR LAMINATED 10000VA CHAS

0

HZ4X-7500A

HZ4X-7500A

SolaHD

PWR XFMR LAMINATED 7500VA CHAS

0

E075E

E075E

SolaHD

PWR XFMR LAMINATED 75VA CHAS MT

0

E300E

E300E

SolaHD

PWR XFMR LAMINATED 300VA CHAS MT

0

HT5F9AS

HT5F9AS

SolaHD

PWR XFMR LAMINATED CHAS MT

0

HZ1210000R

HZ1210000R

SolaHD

PWR XFMR LAMINATED 10000VA CHAS

0

HSS12F1BS

HSS12F1BS

SolaHD

PWR XFMR LAMINATED 1000VA CHAS

0

E750E

E750E

SolaHD

PWR XFMR LAMINATED 750VA CHAS MT

0

E150EW

E150EW

SolaHD

PWR XFMR LAMINATED 150VA CHAS MT

0

E050TF

E050TF

SolaHD

PWR XFMR LAMINATED 50VA CHAS MT

0

HZ125000R

HZ125000R

SolaHD

PWR XFMR LAMINATED 5000VA CHAS

0

HS5F25BS

HS5F25BS

SolaHD

TRANSFORMER 50VA - 45KVA

0

Power Transformers

1. Overview

Power transformers are static electrical devices that transfer energy between circuits through electromagnetic induction. They enable voltage conversion (step-up/step-down) while maintaining galvanic isolation. These components are fundamental in power distribution systems, renewable energy integration, and industrial equipment, ensuring efficient energy transmission and voltage level adaptation.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Distribution TransformersMedium voltage conversion (1kV-36kV), compact designUrban power grids, residential areas
Transmission TransformersHigh voltage (66kV-800kV), grid stability focusSubstations, long-distance power lines
Instrument TransformersMeasurement and protection (CT/VT types)Energy metering, relay protection
Specialty TransformersCustom configurations (furnace, traction, marine)Industrial furnaces, railway systems

3. Structure and Components

Typical construction includes:

  • Core: Grain-oriented silicon steel laminations for magnetic flux path
  • Windings: Primary/secondary copper/aluminum coils with insulation layers
  • Insulation: Mineral oil, synthetic esters, or solid materials (e.g., epoxy)
  • Cooling System: Radiator tanks, fans, or forced-oil circulation
  • Tap Changer: On-load/off-load voltage regulation mechanism
  • Protection: Buchholz relay, pressure relief valves, temperature sensors

4. Key Technical Parameters

ParameterTypical RangeSignificance
Rated Voltage230V-800kVDetermines system compatibility
Power Capacity50kVA-1000MVADefines energy throughput
Voltage Ratio1:1 to 1:20Specifies transformation ratio
Efficiency95%-99.5%Impacts operational costs
Short Circuit Impedance4%-20%Affects fault current limitation
Insulation ClassA (105 C) to C (220 C)Determines thermal endurance

5. Application Areas

Major sectors include:

  • Electricity distribution networks (urban/rural)
  • Renewable energy systems (wind/solar grid-tied inverters)
  • Industrial machinery (CNC, smelters, compressors)
  • Railway traction systems (15kV-25kV conversion)
  • Data centers (HVDC conversion systems)

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Siemens EnergyBlue TransformersEnvironmentally friendly synthetic ester insulation
Asea Brown Boveri (ABB)550kV UHV Transformer 500kV DC transmission capability
General Electric (GE)Premier SeriesSmart monitoring with Predictivity analytics
Mitsubishi Electric330MVA Traction TransformerCompact design for Shinkansen trains

7. Selection Guidelines

Key considerations:

  • Voltage levels (primary/secondary requirements)
  • Load profile (continuous vs. intermittent duty)
  • Cooling requirements (ONAN/ONAF/OFAF modes)
  • Environmental conditions (temperature, altitude, seismic zones)
  • Protection features (IP rating, fire resistance)
  • Smart grid compatibility (IoT sensor integration)

Case Study: Wind farm grid connection selected 33/132kV ONAF-cooled transformer with 12% impedance to meet fault ride-through requirements.

8. Industry Trends

Current development directions:

  • Smart transformers with real-time monitoring (IEEE C57.163 compliant)
  • Amorphous metal core adoption (50% core loss reduction)
  • Hydrogen-cooled systems for offshore applications
  • Modular solid-state transformer (SST) prototypes (DOE GRID DATA initiative)
  • Increased demand for 132kV+ mobile transformers in disaster recovery

Market forecasts indicate 6.2% CAGR through 2030, driven by grid modernization and EV charging infrastructure expansion.

RFQ BOM Call Skype Email
Top