Power Transformers

Image Part Number Description / PDF Quantity Rfq
AHI05010

AHI05010

Zettler Magnetics

PWR XFMR LAMINATED 5.0VA TH

0

AHI02520

AHI02520

Zettler Magnetics

PWR XFMR LAMINATED 2.5VA TH

30

BV301S12020-ZU

BV301S12020-ZU

Zettler Magnetics

PWR XFMR LAMINATED 2VA TH

0

AH40012

AH40012

Zettler Magnetics

PWR XFMR LAMINATED 6.0VA TH

6

ADH30010

ADH30010

Zettler Magnetics

PWR XFMR LAMINATED 2.4VA TH

58

AHI05016

AHI05016

Zettler Magnetics

PWR XFMR LAMINATED 5.0VA TH

30

ADH20028

ADH20028

Zettler Magnetics

PWR XFMR LAMINATED 1.1VA TH

30

BV301S06010-ZU

BV301S06010-ZU

Zettler Magnetics

PWR XFMR LAMINATED 1VA TH

101

BV301S09010-ZU

BV301S09010-ZU

Zettler Magnetics

PWR XFMR LAMINATED 1VA TH

97

AH20012

AH20012

Zettler Magnetics

PWR XFMR LAMINATED 1.1VA TH

28

AH20028

AH20028

Zettler Magnetics

PWR XFMR LAMINATED 1.1VA TH

30

AHI01010

AHI01010

Zettler Magnetics

PWR XFMR LAMINATED 10VA TH

30

AHI05028

AHI05028

Zettler Magnetics

PWR XFMR LAMINATED 5.0VA TH

0

AHI02510

AHI02510

Zettler Magnetics

PWR XFMR LAMINATED 2.5VA TH

30

AHI01028

AHI01028

Zettler Magnetics

PWR XFMR LAMINATED 10VA TH

35

BV302S06006-ZU

BV302S06006-ZU

Zettler Magnetics

PWR XFMR LAMINATED 0.6VA TH

0

ADH40010

ADH40010

Zettler Magnetics

PWR XFMR LAMINATED 6.0VA TH

6

ADH20016

ADH20016

Zettler Magnetics

PWR XFMR LAMINATED 1.1VA TH

30

BV302S09006-ZU

BV302S09006-ZU

Zettler Magnetics

PWR XFMR LAMINATED 0.6VA TH

121

ADH40024

ADH40024

Zettler Magnetics

PWR XFMR LAMINATED 6.0VA TH

0

Power Transformers

1. Overview

Power transformers are static electrical devices that transfer energy between circuits through electromagnetic induction. They enable voltage conversion (step-up/step-down) while maintaining galvanic isolation. These components are fundamental in power distribution systems, renewable energy integration, and industrial equipment, ensuring efficient energy transmission and voltage level adaptation.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Distribution TransformersMedium voltage conversion (1kV-36kV), compact designUrban power grids, residential areas
Transmission TransformersHigh voltage (66kV-800kV), grid stability focusSubstations, long-distance power lines
Instrument TransformersMeasurement and protection (CT/VT types)Energy metering, relay protection
Specialty TransformersCustom configurations (furnace, traction, marine)Industrial furnaces, railway systems

3. Structure and Components

Typical construction includes:

  • Core: Grain-oriented silicon steel laminations for magnetic flux path
  • Windings: Primary/secondary copper/aluminum coils with insulation layers
  • Insulation: Mineral oil, synthetic esters, or solid materials (e.g., epoxy)
  • Cooling System: Radiator tanks, fans, or forced-oil circulation
  • Tap Changer: On-load/off-load voltage regulation mechanism
  • Protection: Buchholz relay, pressure relief valves, temperature sensors

4. Key Technical Parameters

ParameterTypical RangeSignificance
Rated Voltage230V-800kVDetermines system compatibility
Power Capacity50kVA-1000MVADefines energy throughput
Voltage Ratio1:1 to 1:20Specifies transformation ratio
Efficiency95%-99.5%Impacts operational costs
Short Circuit Impedance4%-20%Affects fault current limitation
Insulation ClassA (105 C) to C (220 C)Determines thermal endurance

5. Application Areas

Major sectors include:

  • Electricity distribution networks (urban/rural)
  • Renewable energy systems (wind/solar grid-tied inverters)
  • Industrial machinery (CNC, smelters, compressors)
  • Railway traction systems (15kV-25kV conversion)
  • Data centers (HVDC conversion systems)

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Siemens EnergyBlue TransformersEnvironmentally friendly synthetic ester insulation
Asea Brown Boveri (ABB)550kV UHV Transformer 500kV DC transmission capability
General Electric (GE)Premier SeriesSmart monitoring with Predictivity analytics
Mitsubishi Electric330MVA Traction TransformerCompact design for Shinkansen trains

7. Selection Guidelines

Key considerations:

  • Voltage levels (primary/secondary requirements)
  • Load profile (continuous vs. intermittent duty)
  • Cooling requirements (ONAN/ONAF/OFAF modes)
  • Environmental conditions (temperature, altitude, seismic zones)
  • Protection features (IP rating, fire resistance)
  • Smart grid compatibility (IoT sensor integration)

Case Study: Wind farm grid connection selected 33/132kV ONAF-cooled transformer with 12% impedance to meet fault ride-through requirements.

8. Industry Trends

Current development directions:

  • Smart transformers with real-time monitoring (IEEE C57.163 compliant)
  • Amorphous metal core adoption (50% core loss reduction)
  • Hydrogen-cooled systems for offshore applications
  • Modular solid-state transformer (SST) prototypes (DOE GRID DATA initiative)
  • Increased demand for 132kV+ mobile transformers in disaster recovery

Market forecasts indicate 6.2% CAGR through 2030, driven by grid modernization and EV charging infrastructure expansion.