Power Transformers

Image Part Number Description / PDF Quantity Rfq
VPP20-500

VPP20-500

Triad Magnetics

PWR XFMR LAMINATED 10VA TH

152615

F16-070-C2

F16-070-C2

Triad Magnetics

PWR XFMR LAMINATED 1.1VA TH

117

FS12-2850

FS12-2850

Triad Magnetics

PWR XFMR LAMINATED 36VA TH

0

F-41X

F-41X

Triad Magnetics

PWR XFMR LAMINATED 50.4VA CHAS

581

VPL14-360

VPL14-360

Triad Magnetics

PWR XFMR LAMINATED 5.0VA CHAS MT

28

FS28-1300-C2

FS28-1300-C2

Triad Magnetics

PWR XFMR LAMINATED 36VA TH

25

F4-28

F4-28

Triad Magnetics

PWR XFMR LAMINATED 6VA CHAS MT

102

F10-1200-C2

F10-1200-C2

Triad Magnetics

PWR XFMR LAMINATED 12VA TH

0

FS16-400

FS16-400

Triad Magnetics

PWR XFMR LAMINATED 6VA TH

83762

F-401U

F-401U

Triad Magnetics

PWR XFMR LAMINATED 240VA CHAS MT

257

VPP12-2400

VPP12-2400

Triad Magnetics

PWR XFMR LAMINATED 30VA TH

0

F120-300

F120-300

Triad Magnetics

PWR XFMR LAMINATED 36VA TH

967

F-218X

F-218X

Triad Magnetics

PWR XFMR LAMINATED 24VA CHAS MT

17

FP56-200

FP56-200

Triad Magnetics

PWR XFMR LAMINATED 12VA TH

19102

F-91X

F-91X

Triad Magnetics

PWR XFMR LAMINATED CHASSIS MT

259

VPS12-2000-B

VPS12-2000-B

Triad Magnetics

PWR XFMR LAMINATED 25VA CHAS MT

0

VPS10-13000

VPS10-13000

Triad Magnetics

PWR XFMR LAMINATED 130VA CHAS MT

8169

VPM240-2080

VPM240-2080

Triad Magnetics

PWR XFMR TORO 500VA CHAS MT

152

FS28-085-C2

FS28-085-C2

Triad Magnetics

PWR XFMR LAMINATED 2.4VA TH

239

VPS20-4000-B

VPS20-4000-B

Triad Magnetics

PWR XFMR LAMINATED 80VA CHAS MT

0

Power Transformers

1. Overview

Power transformers are static electrical devices that transfer energy between circuits through electromagnetic induction. They enable voltage conversion (step-up/step-down) while maintaining galvanic isolation. These components are fundamental in power distribution systems, renewable energy integration, and industrial equipment, ensuring efficient energy transmission and voltage level adaptation.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Distribution TransformersMedium voltage conversion (1kV-36kV), compact designUrban power grids, residential areas
Transmission TransformersHigh voltage (66kV-800kV), grid stability focusSubstations, long-distance power lines
Instrument TransformersMeasurement and protection (CT/VT types)Energy metering, relay protection
Specialty TransformersCustom configurations (furnace, traction, marine)Industrial furnaces, railway systems

3. Structure and Components

Typical construction includes:

  • Core: Grain-oriented silicon steel laminations for magnetic flux path
  • Windings: Primary/secondary copper/aluminum coils with insulation layers
  • Insulation: Mineral oil, synthetic esters, or solid materials (e.g., epoxy)
  • Cooling System: Radiator tanks, fans, or forced-oil circulation
  • Tap Changer: On-load/off-load voltage regulation mechanism
  • Protection: Buchholz relay, pressure relief valves, temperature sensors

4. Key Technical Parameters

ParameterTypical RangeSignificance
Rated Voltage230V-800kVDetermines system compatibility
Power Capacity50kVA-1000MVADefines energy throughput
Voltage Ratio1:1 to 1:20Specifies transformation ratio
Efficiency95%-99.5%Impacts operational costs
Short Circuit Impedance4%-20%Affects fault current limitation
Insulation ClassA (105 C) to C (220 C)Determines thermal endurance

5. Application Areas

Major sectors include:

  • Electricity distribution networks (urban/rural)
  • Renewable energy systems (wind/solar grid-tied inverters)
  • Industrial machinery (CNC, smelters, compressors)
  • Railway traction systems (15kV-25kV conversion)
  • Data centers (HVDC conversion systems)

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Siemens EnergyBlue TransformersEnvironmentally friendly synthetic ester insulation
Asea Brown Boveri (ABB)550kV UHV Transformer 500kV DC transmission capability
General Electric (GE)Premier SeriesSmart monitoring with Predictivity analytics
Mitsubishi Electric330MVA Traction TransformerCompact design for Shinkansen trains

7. Selection Guidelines

Key considerations:

  • Voltage levels (primary/secondary requirements)
  • Load profile (continuous vs. intermittent duty)
  • Cooling requirements (ONAN/ONAF/OFAF modes)
  • Environmental conditions (temperature, altitude, seismic zones)
  • Protection features (IP rating, fire resistance)
  • Smart grid compatibility (IoT sensor integration)

Case Study: Wind farm grid connection selected 33/132kV ONAF-cooled transformer with 12% impedance to meet fault ride-through requirements.

8. Industry Trends

Current development directions:

  • Smart transformers with real-time monitoring (IEEE C57.163 compliant)
  • Amorphous metal core adoption (50% core loss reduction)
  • Hydrogen-cooled systems for offshore applications
  • Modular solid-state transformer (SST) prototypes (DOE GRID DATA initiative)
  • Increased demand for 132kV+ mobile transformers in disaster recovery

Market forecasts indicate 6.2% CAGR through 2030, driven by grid modernization and EV charging infrastructure expansion.

RFQ BOM Call Skype Email
Top