Power Transformers

Image Part Number Description / PDF Quantity Rfq
FS20-1000-C2

FS20-1000-C2

Triad Magnetics

PWR XFMR LAMINATED 20VA TH

2

FS48-050-C2

FS48-050-C2

Triad Magnetics

PWR XFMR LAMINATED 2.4VA TH

43

VPS20-8800

VPS20-8800

Triad Magnetics

PWR XFMR LAMINATED 175VA CHAS MT

98

VPT230-1090-B

VPT230-1090-B

Triad Magnetics

PWR XFMR TORO 250VA CHAS MT

0

F-59X

F-59X

Triad Magnetics

PWR XFMR LAMINATED 24VA CHAS MT

24244

VPP20-250

VPP20-250

Triad Magnetics

PWR XFMR LAMINATED 5VA TH

536

F-6X

F-6X

Triad Magnetics

PWR XFMR LAMINATED 15VA CHAS MT

286

F8-24

F8-24

Triad Magnetics

PWR XFMR LAMINATED 100VA CHAS MT

397760

TCT40-06E07K-B

TCT40-06E07K-B

Triad Magnetics

PWR XFMR LAMINATED 40VA CHAS MT

704

VPP36-070

VPP36-070

Triad Magnetics

PWR XFMR LAMINATED 2.5VA TH

379723

VPS24-1000-B

VPS24-1000-B

Triad Magnetics

PWR XFMR LAMINATED 25VA CHAS MT

180

VPM100-5000

VPM100-5000

Triad Magnetics

PWR XFMR TORO 500VA CHAS MT

8

F4-20

F4-20

Triad Magnetics

PWR XFMR LAMINATED 6VA CHAS MT

132

VPS24-3300

VPS24-3300

Triad Magnetics

PWR XFMR LAMINATED 80VA CHAS MT

175208

F-399U

F-399U

Triad Magnetics

PWR XFMR LAMINATED 192VA CHAS MT

40

FS12-090-C2

FS12-090-C2

Triad Magnetics

PWR XFMR LAMINATED 1.1VA TH

5776

F-40X

F-40X

Triad Magnetics

PWR XFMR LAMINATED 26.8VA CHAS

39101

VPL20-2500

VPL20-2500

Triad Magnetics

PWR XFMR LAMINATED 50.0VA CHAS

393

F-14X

F-14X

Triad Magnetics

PWR XFMR LAMINATED 7.56VA CHAS

2562

VPP12-200-B

VPP12-200-B

Triad Magnetics

PWR XFMR LAMINATED 2.5VA TH

700

Power Transformers

1. Overview

Power transformers are static electrical devices that transfer energy between circuits through electromagnetic induction. They enable voltage conversion (step-up/step-down) while maintaining galvanic isolation. These components are fundamental in power distribution systems, renewable energy integration, and industrial equipment, ensuring efficient energy transmission and voltage level adaptation.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Distribution TransformersMedium voltage conversion (1kV-36kV), compact designUrban power grids, residential areas
Transmission TransformersHigh voltage (66kV-800kV), grid stability focusSubstations, long-distance power lines
Instrument TransformersMeasurement and protection (CT/VT types)Energy metering, relay protection
Specialty TransformersCustom configurations (furnace, traction, marine)Industrial furnaces, railway systems

3. Structure and Components

Typical construction includes:

  • Core: Grain-oriented silicon steel laminations for magnetic flux path
  • Windings: Primary/secondary copper/aluminum coils with insulation layers
  • Insulation: Mineral oil, synthetic esters, or solid materials (e.g., epoxy)
  • Cooling System: Radiator tanks, fans, or forced-oil circulation
  • Tap Changer: On-load/off-load voltage regulation mechanism
  • Protection: Buchholz relay, pressure relief valves, temperature sensors

4. Key Technical Parameters

ParameterTypical RangeSignificance
Rated Voltage230V-800kVDetermines system compatibility
Power Capacity50kVA-1000MVADefines energy throughput
Voltage Ratio1:1 to 1:20Specifies transformation ratio
Efficiency95%-99.5%Impacts operational costs
Short Circuit Impedance4%-20%Affects fault current limitation
Insulation ClassA (105 C) to C (220 C)Determines thermal endurance

5. Application Areas

Major sectors include:

  • Electricity distribution networks (urban/rural)
  • Renewable energy systems (wind/solar grid-tied inverters)
  • Industrial machinery (CNC, smelters, compressors)
  • Railway traction systems (15kV-25kV conversion)
  • Data centers (HVDC conversion systems)

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Siemens EnergyBlue TransformersEnvironmentally friendly synthetic ester insulation
Asea Brown Boveri (ABB)550kV UHV Transformer 500kV DC transmission capability
General Electric (GE)Premier SeriesSmart monitoring with Predictivity analytics
Mitsubishi Electric330MVA Traction TransformerCompact design for Shinkansen trains

7. Selection Guidelines

Key considerations:

  • Voltage levels (primary/secondary requirements)
  • Load profile (continuous vs. intermittent duty)
  • Cooling requirements (ONAN/ONAF/OFAF modes)
  • Environmental conditions (temperature, altitude, seismic zones)
  • Protection features (IP rating, fire resistance)
  • Smart grid compatibility (IoT sensor integration)

Case Study: Wind farm grid connection selected 33/132kV ONAF-cooled transformer with 12% impedance to meet fault ride-through requirements.

8. Industry Trends

Current development directions:

  • Smart transformers with real-time monitoring (IEEE C57.163 compliant)
  • Amorphous metal core adoption (50% core loss reduction)
  • Hydrogen-cooled systems for offshore applications
  • Modular solid-state transformer (SST) prototypes (DOE GRID DATA initiative)
  • Increased demand for 132kV+ mobile transformers in disaster recovery

Market forecasts indicate 6.2% CAGR through 2030, driven by grid modernization and EV charging infrastructure expansion.