Power Transformers

Image Part Number Description / PDF Quantity Rfq
4700-08K05AA500

4700-08K05AA500

TE Connectivity Potter & Brumfield Relays

POWER TRANSFORMER CHASSIS

0

4700-08K18BB784

4700-08K18BB784

TE Connectivity Potter & Brumfield Relays

POWER TRANSFORMER CHASSIS

0

4000-04E07AE999

4000-04E07AE999

TE Connectivity Potter & Brumfield Relays

PWR XFMR LAMINATED 40VA CHAS MT

0

4000-09E07BB80

4000-09E07BB80

TE Connectivity Potter & Brumfield Relays

POWER TRANSFORMER CHASSIS

0

4000-47J15AE999

4000-47J15AE999

TE Connectivity Potter & Brumfield Relays

POWER TRANSFORMER CHASSIS

0

4000-20M04BB908

4000-20M04BB908

TE Connectivity Potter & Brumfield Relays

POWER TRANSFORMER CHASSIS

0

4000-97M04BB865

4000-97M04BB865

TE Connectivity Potter & Brumfield Relays

POWER TRANSFORMER CHASSIS

0

4000-02A19K875

4000-02A19K875

TE Connectivity Potter & Brumfield Relays

POWER TRANSFORMER CHASSIS

0

4700-280L15BB634

4700-280L15BB634

TE Connectivity Potter & Brumfield Relays

POWER TRANSFORMER CHASSIS

0

4700Y08K18K999

4700Y08K18K999

TE Connectivity Potter & Brumfield Relays

PWR XFMR LAMINATED 100VA CHAS MT

0

4000-01C02X559

4000-01C02X559

TE Connectivity Potter & Brumfield Relays

POWER TRANSFORMER CHASSIS

0

4000-212E33K500A

4000-212E33K500A

TE Connectivity Potter & Brumfield Relays

POWER TRANSFORMER CHASSIS

0

4000-60E07AE347

4000-60E07AE347

TE Connectivity Potter & Brumfield Relays

POWER TRANSFORMER CHASSIS

0

4000-01C02BC999

4000-01C02BC999

TE Connectivity Potter & Brumfield Relays

PWR XFMR LAMINATED 20VA CHAS MT

0

4000-01V18G148

4000-01V18G148

TE Connectivity Potter & Brumfield Relays

POWER TRANSFORMER CHASSIS

0

7122C

7122C

TE Connectivity Potter & Brumfield Relays

POWER TRANSFORMER CHASSIS

0

4000W02V18BB39

4000W02V18BB39

TE Connectivity Potter & Brumfield Relays

POWER TRANSFORMER CHASSIS

0

4100-369J41K216

4100-369J41K216

TE Connectivity Potter & Brumfield Relays

POWER TRANSFORMER CHASSIS

0

4100-85K18K353

4100-85K18K353

TE Connectivity Potter & Brumfield Relays

POWER TRANSFORMER CHASSIS

0

4000-02M04K52

4000-02M04K52

TE Connectivity Potter & Brumfield Relays

POWER TRANSFORMER CHASSIS

0

Power Transformers

1. Overview

Power transformers are static electrical devices that transfer energy between circuits through electromagnetic induction. They enable voltage conversion (step-up/step-down) while maintaining galvanic isolation. These components are fundamental in power distribution systems, renewable energy integration, and industrial equipment, ensuring efficient energy transmission and voltage level adaptation.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Distribution TransformersMedium voltage conversion (1kV-36kV), compact designUrban power grids, residential areas
Transmission TransformersHigh voltage (66kV-800kV), grid stability focusSubstations, long-distance power lines
Instrument TransformersMeasurement and protection (CT/VT types)Energy metering, relay protection
Specialty TransformersCustom configurations (furnace, traction, marine)Industrial furnaces, railway systems

3. Structure and Components

Typical construction includes:

  • Core: Grain-oriented silicon steel laminations for magnetic flux path
  • Windings: Primary/secondary copper/aluminum coils with insulation layers
  • Insulation: Mineral oil, synthetic esters, or solid materials (e.g., epoxy)
  • Cooling System: Radiator tanks, fans, or forced-oil circulation
  • Tap Changer: On-load/off-load voltage regulation mechanism
  • Protection: Buchholz relay, pressure relief valves, temperature sensors

4. Key Technical Parameters

ParameterTypical RangeSignificance
Rated Voltage230V-800kVDetermines system compatibility
Power Capacity50kVA-1000MVADefines energy throughput
Voltage Ratio1:1 to 1:20Specifies transformation ratio
Efficiency95%-99.5%Impacts operational costs
Short Circuit Impedance4%-20%Affects fault current limitation
Insulation ClassA (105 C) to C (220 C)Determines thermal endurance

5. Application Areas

Major sectors include:

  • Electricity distribution networks (urban/rural)
  • Renewable energy systems (wind/solar grid-tied inverters)
  • Industrial machinery (CNC, smelters, compressors)
  • Railway traction systems (15kV-25kV conversion)
  • Data centers (HVDC conversion systems)

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Siemens EnergyBlue TransformersEnvironmentally friendly synthetic ester insulation
Asea Brown Boveri (ABB)550kV UHV Transformer 500kV DC transmission capability
General Electric (GE)Premier SeriesSmart monitoring with Predictivity analytics
Mitsubishi Electric330MVA Traction TransformerCompact design for Shinkansen trains

7. Selection Guidelines

Key considerations:

  • Voltage levels (primary/secondary requirements)
  • Load profile (continuous vs. intermittent duty)
  • Cooling requirements (ONAN/ONAF/OFAF modes)
  • Environmental conditions (temperature, altitude, seismic zones)
  • Protection features (IP rating, fire resistance)
  • Smart grid compatibility (IoT sensor integration)

Case Study: Wind farm grid connection selected 33/132kV ONAF-cooled transformer with 12% impedance to meet fault ride-through requirements.

8. Industry Trends

Current development directions:

  • Smart transformers with real-time monitoring (IEEE C57.163 compliant)
  • Amorphous metal core adoption (50% core loss reduction)
  • Hydrogen-cooled systems for offshore applications
  • Modular solid-state transformer (SST) prototypes (DOE GRID DATA initiative)
  • Increased demand for 132kV+ mobile transformers in disaster recovery

Market forecasts indicate 6.2% CAGR through 2030, driven by grid modernization and EV charging infrastructure expansion.