Power Transformers

Image Part Number Description / PDF Quantity Rfq
ST-5-48

ST-5-48

Signal Transformer

PWR XFMR LAMINATED 12VA TH

0

182Q9

182Q9

Hammond Manufacturing

PWR XFMR TORO 120VA CHAS MT

0

F-370P

F-370P

Triad Magnetics

PWR XFMR LAMINATED 24VA TH

49

ST-6-56

ST-6-56

Signal Transformer

PWR XFMR LAMINATED 20VA TH

0

241-3-20

241-3-20

Signal Transformer

PWR XFMR LAMINATED 2.4VA CHAS MT

0

PT120CF

PT120CF

Hammond Manufacturing

PWR XFMR LAMINATED CHAS MT

18

FP12-3800

FP12-3800

Triad Magnetics

PWR XFMR LAMINATED 48VA TH

70

14A-10R-10

14A-10R-10

Signal Transformer

PWR XFMR LAMINATED 10VA TH

601

FD4-36

FD4-36

Triad Magnetics

PWR XFMR LAMINATED 6VA CHAS MT

160

MED2500

MED2500

Amgis

PWR XFMR TORO 2500VA CHAS MT

0

AH40016

AH40016

Zettler Magnetics

PWR XFMR LAMINATED 6.0VA TH

25

167M36

167M36

Hammond Manufacturing

PWR XFMR LAMINATED 108VA CHAS MT

2

VPP10-3000

VPP10-3000

Triad Magnetics

PWR XFMR LAMINATED 30VA TH

107560

372LX

372LX

Hammond Manufacturing

PWR XFMR LAMINATED 520VA CHAS MT

2

MPI-400-12

MPI-400-12

Signal Transformer

PWR XFMR LAMINATED 400VA CHAS MT

0

F20-1000-C2

F20-1000-C2

Triad Magnetics

PWR XFMR LAMINATED 20VA TH

95

373EX

373EX

Hammond Manufacturing

PWR XFMR LAMINATED 311VA CHAS MT

2

3FD-510

3FD-510

Tamura

PWR XFMR LAMINATED 12VA TH

0

VPL25-1000

VPL25-1000

Triad Magnetics

PWR XFMR LAMINATED 25.0VA CHAS

40

182N15

182N15

Hammond Manufacturing

PWR XFMR TORO 120VA CHAS MT

0

Power Transformers

1. Overview

Power transformers are static electrical devices that transfer energy between circuits through electromagnetic induction. They enable voltage conversion (step-up/step-down) while maintaining galvanic isolation. These components are fundamental in power distribution systems, renewable energy integration, and industrial equipment, ensuring efficient energy transmission and voltage level adaptation.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Distribution TransformersMedium voltage conversion (1kV-36kV), compact designUrban power grids, residential areas
Transmission TransformersHigh voltage (66kV-800kV), grid stability focusSubstations, long-distance power lines
Instrument TransformersMeasurement and protection (CT/VT types)Energy metering, relay protection
Specialty TransformersCustom configurations (furnace, traction, marine)Industrial furnaces, railway systems

3. Structure and Components

Typical construction includes:

  • Core: Grain-oriented silicon steel laminations for magnetic flux path
  • Windings: Primary/secondary copper/aluminum coils with insulation layers
  • Insulation: Mineral oil, synthetic esters, or solid materials (e.g., epoxy)
  • Cooling System: Radiator tanks, fans, or forced-oil circulation
  • Tap Changer: On-load/off-load voltage regulation mechanism
  • Protection: Buchholz relay, pressure relief valves, temperature sensors

4. Key Technical Parameters

ParameterTypical RangeSignificance
Rated Voltage230V-800kVDetermines system compatibility
Power Capacity50kVA-1000MVADefines energy throughput
Voltage Ratio1:1 to 1:20Specifies transformation ratio
Efficiency95%-99.5%Impacts operational costs
Short Circuit Impedance4%-20%Affects fault current limitation
Insulation ClassA (105 C) to C (220 C)Determines thermal endurance

5. Application Areas

Major sectors include:

  • Electricity distribution networks (urban/rural)
  • Renewable energy systems (wind/solar grid-tied inverters)
  • Industrial machinery (CNC, smelters, compressors)
  • Railway traction systems (15kV-25kV conversion)
  • Data centers (HVDC conversion systems)

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Siemens EnergyBlue TransformersEnvironmentally friendly synthetic ester insulation
Asea Brown Boveri (ABB)550kV UHV Transformer 500kV DC transmission capability
General Electric (GE)Premier SeriesSmart monitoring with Predictivity analytics
Mitsubishi Electric330MVA Traction TransformerCompact design for Shinkansen trains

7. Selection Guidelines

Key considerations:

  • Voltage levels (primary/secondary requirements)
  • Load profile (continuous vs. intermittent duty)
  • Cooling requirements (ONAN/ONAF/OFAF modes)
  • Environmental conditions (temperature, altitude, seismic zones)
  • Protection features (IP rating, fire resistance)
  • Smart grid compatibility (IoT sensor integration)

Case Study: Wind farm grid connection selected 33/132kV ONAF-cooled transformer with 12% impedance to meet fault ride-through requirements.

8. Industry Trends

Current development directions:

  • Smart transformers with real-time monitoring (IEEE C57.163 compliant)
  • Amorphous metal core adoption (50% core loss reduction)
  • Hydrogen-cooled systems for offshore applications
  • Modular solid-state transformer (SST) prototypes (DOE GRID DATA initiative)
  • Increased demand for 132kV+ mobile transformers in disaster recovery

Market forecasts indicate 6.2% CAGR through 2030, driven by grid modernization and EV charging infrastructure expansion.

RFQ BOM Call Skype Email
Top