Isolation Transformers and Autotransformers, Step Up, Step Down

Image Part Number Description / PDF Quantity Rfq
HS19B250

HS19B250

SolaHD

0.250KVA 120X240-12/24 BB

4

E81H300S

E81H300S

SolaHD

300KVA 480D-480Y

0

DT631H220S

DT631H220S

SolaHD

220KVA 575D-230Y SCR DRIVE

0

DT661H175S

DT661H175S

SolaHD

175KVA 460D-230Y SCR DRIVE

0

E2H150S

E2H150S

SolaHD

150KVA 480D-208Y

0

23-13-030-2

23-13-030-2

SolaHD

30VA CVS VOLTAGE REGULATOR

0

E5H45S

E5H45S

SolaHD

LVGP DOE2016 45KVA 480D-240DCT

0

E5HF300S

E5HF300S

SolaHD

300KVA 480D-240DCT 115C

0

F2F45S

F2F45S

SolaHD

45KVA 480D-208Y C1D2

0

HS20F2A

HS20F2A

SolaHD

2KVA 120X240-16/32 BB

2

DT661H118S

DT661H118S

SolaHD

118KVA 460D-230Y SCR DRIVE

0

DT631H440S

DT631H440S

SolaHD

440KVA 575D-230Y SCR DRIVE

0

E3H150S

E3H150S

SolaHD

150KVA 208D-208Y

0

DT651H11S

DT651H11S

SolaHD

11KVA 460D-460Y SCR DRIVE

0

E2H300S

E2H300S

SolaHD

300KVA 480D-208Y

0

E81H15S

E81H15S

SolaHD

15KVA 480D-480Y

0

DT661H14S

DT661H14S

SolaHD

14KVA 460D-230Y SCR DRIVE

0

DT631H118S

DT631H118S

SolaHD

118KVA 575D-230Y SCR DRIVE

0

DT651H75S

DT651H75S

SolaHD

75KVA 460D-460Y SCR DRIVE

0

DT631H175S

DT631H175S

SolaHD

175KVA 575D-230Y SCR DRIVE

0

Isolation Transformers and Autotransformers, Step Up, Step Down

1. Overview

Transformers are static electrical devices that transfer energy between circuits through electromagnetic induction. Isolation transformers provide galvanic separation between primary and secondary circuits, while autotransformers share a common winding. Step-up/down transformers adjust voltage levels (increasing/decreasing respectively) for power transmission, distribution, and equipment compatibility. These devices are critical in power systems, industrial machinery, renewable energy, and electronic applications.

2. Main Types and Functional Classification

TypeFunctionalityApplications
Isolation TransformerSeparates primary/secondary circuits for safety and noise reductionHospitals, data centers, laboratory equipment
AutotransformerSingle winding with shared magnetic and electrical pathVoltage regulation in industrial motors, railway systems
Step-Up TransformerIncreases voltage (N2>N1) for long-distance transmissionPower plants, grid substations
Step-Down TransformerDecreases voltage (N2<N1) for end-use compatibilityHousehold appliances, distribution networks

3. Structure and Components

Typical construction includes:

  • Core: Silicon steel laminations to reduce eddy current losses
  • Windings: Copper/aluminum coils with insulation layers (primary/secondary for isolation transformers, single tapped winding for autotransformers)
  • Insulation: Mineral oil, epoxy resin, or air-based dielectric systems
  • Enclosure: Metal housing with cooling vents or radiators
  • Terminals: Safety-rated connectors for input/output connections

4. Key Technical Specifications

ParameterSignificanceTypical Range
Turns RatioDetermines voltage transformation ratio0.1:1 to 10:1
Power RatingDefines maximum VA/kVA capacity50 VA - 100 MVA
Insulation ClassSpecifies thermal and dielectric withstand capabilityClass I/II, 150-220 C
EfficiencyEnergy conversion ratio ( = Pout/Pin)95-99% (large units)
Frequency RangeOperational frequency compatibility50/60 Hz, 400 Hz (aviation)

5. Application Areas

  • Energy: Grid transmission (step-up), distribution networks (step-down)
  • Healthcare: Isolation transformers for patient-connected medical devices
  • Manufacturing: Autotransformers for motor starting and voltage control
  • Electronics: PCB-mounted step-down transformers for AC-DC conversion
  • Renewables: Step-up transformers in solar inverters and wind turbines

6. Leading Manufacturers and Products

ManufacturerKey Products
ABBRESIBLOC dry-type transformers, 3-phase isolation units
SiemensSiempreGuard encapsulated transformers
General ElectricStep-up transformers for wind energy (110MVA/132kV)
Delta ElectronicsAutotransformers for servo motor control systems

7. Selection Guidelines

Key considerations:

  • Voltage and current requirements (including tolerance margins)
  • Isolation necessity (double insulation vs. autotransformer cost-benefit analysis)
  • Environmental factors (temperature, humidity, altitude)
  • Compliance standards (UL 5085, IEC 61558, IEEE C57.12.00)
  • Space constraints (dry-type vs. oil-immersed units)
  • Short-circuit protection requirements
Example: For medical imaging equipment, select a Class I isolation transformer with reinforced insulation and leakage current <10 A.

8. Industry Trends

Emerging developments include:

  • High-frequency transformers for compact converter systems (SiC/GaN inverters)
  • Smart transformers with integrated IoT sensors for predictive maintenance
  • Biodegradable ester-based insulation fluids
  • Amorphous core designs reducing no-load losses by 60-70%
  • Modular transformer arrays for renewable energy microgrids