Isolation Transformers and Autotransformers, Step Up, Step Down

Image Part Number Description / PDF Quantity Rfq
N-66A

N-66A

Triad Magnetics

TRANS 250VA 115V 2.17A CHASIS MT

33283

N-57M

N-57M

Triad Magnetics

TRANSFORMER ISOL

130

N-92MD

N-92MD

Triad Magnetics

TRANSFORMER ISOL

0

N-6U

N-6U

Triad Magnetics

AUTOTRANSFORMER NON-ISOL 200 VA

28

N-90MD

N-90MD

Triad Magnetics

TRANSFORMER ISOL

16

N-257MG

N-257MG

Triad Magnetics

TRANSFORMER ISOL

80

N-2X

N-2X

Triad Magnetics

AUTOTRANSFORMER NON-ISOL 100 VA

76222

N-55M

N-55M

Triad Magnetics

TRANSFORMER ISOL

24

N-259MG

N-259MG

Triad Magnetics

TRANSFORMER ISOL

65

N-51X

N-51X

Triad Magnetics

TRANSFORMER ISOL

63111

N-3MG

N-3MG

Triad Magnetics

AUTOTRANSFORMER NON-ISOL 85 VA

17

MD-500-U

MD-500-U

Triad Magnetics

MED GRADE ENC ISOLATION XFORMR

45

N-500MG

N-500MG

Triad Magnetics

AUTOTRANSFORMER NON-ISOL 500 VA

432

MD-1000-E

MD-1000-E

Triad Magnetics

MED GRADE ENC ISOLATION XFORMR

519

MD-250-E

MD-250-E

Triad Magnetics

MED GRADE ENC ISOLATION XFORMR

301

N-255MG

N-255MG

Triad Magnetics

TRANSFORMER ISOL

567

N-1X

N-1X

Triad Magnetics

AUTOTRANSFORMER NON-ISOL 50 VA

139

N-4MG

N-4MG

Triad Magnetics

AUTOTRANSFORMER NON-ISOL 150 VA

363

N-68X

N-68X

Triad Magnetics

TRANSFORMER ISOL 50VA 115/230VAC

91183

N-250MG

N-250MG

Triad Magnetics

AUTOTRANSFORMER NON-ISOL 250 VA

6360

Isolation Transformers and Autotransformers, Step Up, Step Down

1. Overview

Transformers are static electrical devices that transfer energy between circuits through electromagnetic induction. Isolation transformers provide galvanic separation between primary and secondary circuits, while autotransformers share a common winding. Step-up/down transformers adjust voltage levels (increasing/decreasing respectively) for power transmission, distribution, and equipment compatibility. These devices are critical in power systems, industrial machinery, renewable energy, and electronic applications.

2. Main Types and Functional Classification

TypeFunctionalityApplications
Isolation TransformerSeparates primary/secondary circuits for safety and noise reductionHospitals, data centers, laboratory equipment
AutotransformerSingle winding with shared magnetic and electrical pathVoltage regulation in industrial motors, railway systems
Step-Up TransformerIncreases voltage (N2>N1) for long-distance transmissionPower plants, grid substations
Step-Down TransformerDecreases voltage (N2<N1) for end-use compatibilityHousehold appliances, distribution networks

3. Structure and Components

Typical construction includes:

  • Core: Silicon steel laminations to reduce eddy current losses
  • Windings: Copper/aluminum coils with insulation layers (primary/secondary for isolation transformers, single tapped winding for autotransformers)
  • Insulation: Mineral oil, epoxy resin, or air-based dielectric systems
  • Enclosure: Metal housing with cooling vents or radiators
  • Terminals: Safety-rated connectors for input/output connections

4. Key Technical Specifications

ParameterSignificanceTypical Range
Turns RatioDetermines voltage transformation ratio0.1:1 to 10:1
Power RatingDefines maximum VA/kVA capacity50 VA - 100 MVA
Insulation ClassSpecifies thermal and dielectric withstand capabilityClass I/II, 150-220 C
EfficiencyEnergy conversion ratio ( = Pout/Pin)95-99% (large units)
Frequency RangeOperational frequency compatibility50/60 Hz, 400 Hz (aviation)

5. Application Areas

  • Energy: Grid transmission (step-up), distribution networks (step-down)
  • Healthcare: Isolation transformers for patient-connected medical devices
  • Manufacturing: Autotransformers for motor starting and voltage control
  • Electronics: PCB-mounted step-down transformers for AC-DC conversion
  • Renewables: Step-up transformers in solar inverters and wind turbines

6. Leading Manufacturers and Products

ManufacturerKey Products
ABBRESIBLOC dry-type transformers, 3-phase isolation units
SiemensSiempreGuard encapsulated transformers
General ElectricStep-up transformers for wind energy (110MVA/132kV)
Delta ElectronicsAutotransformers for servo motor control systems

7. Selection Guidelines

Key considerations:

  • Voltage and current requirements (including tolerance margins)
  • Isolation necessity (double insulation vs. autotransformer cost-benefit analysis)
  • Environmental factors (temperature, humidity, altitude)
  • Compliance standards (UL 5085, IEC 61558, IEEE C57.12.00)
  • Space constraints (dry-type vs. oil-immersed units)
  • Short-circuit protection requirements
Example: For medical imaging equipment, select a Class I isolation transformer with reinforced insulation and leakage current <10 A.

8. Industry Trends

Emerging developments include:

  • High-frequency transformers for compact converter systems (SiC/GaN inverters)
  • Smart transformers with integrated IoT sensors for predictive maintenance
  • Biodegradable ester-based insulation fluids
  • Amorphous core designs reducing no-load losses by 60-70%
  • Modular transformer arrays for renewable energy microgrids