Isolation Transformers and Autotransformers, Step Up, Step Down

Image Part Number Description / PDF Quantity Rfq
170EE

170EE

Hammond Manufacturing

TRANSFORMR AUTO 115-230VAC 750VA

5

IS250HG

IS250HG

Tripp Lite

TRANSF ISO 250W 2OUT HOSP GRADE

0

178FT

178FT

Hammond Manufacturing

TRANSFORMER - TOROIDAL ISOLATION

3

171F

171F

Hammond Manufacturing

TRANSFM ISOL 115 TO 115VAC 750VA

10

T-1500208X120

T-1500208X120

Tecnomatic Corp

TRANSF 1500VA 208-240-480/120

2

240ET

240ET

Hammond Manufacturing

TRANSFORMER TOROIDAL ISOLATION

3

SU20KXFMRT4U

SU20KXFMRT4U

Tripp Lite

STEP-DOWN TRANSFORMER

17

N-66A-B

N-66A-B

Triad Magnetics

TRANS 250VA 115V 2.17A CHASIS MT

0

SU-5

SU-5

Signal Transformer

TRANSFORMER ISOLATION 5000W

1

MD-2400-E

MD-2400-E

Triad Magnetics

MED GRADE ENC ISOLATION XFORMR

2147

MD-250-U

MD-250-U

Triad Magnetics

TRANSFORMER ISOLATION MEDICAL

341

N-57MG

N-57MG

Triad Magnetics

TRANSFORMER ISOL

444

171E

171E

Hammond Manufacturing

TRANSFM ISOL 115 TO 115VAC 500VA

13

T-150208X120

T-150208X120

Tecnomatic Corp

TRANSF 150VA 208-240-480/120

10

T-075208X120

T-075208X120

Tecnomatic Corp

TRANSF 75VA 208-240-480/120

10

172F

172F

Hammond Manufacturing

ISOLATION STEP DOWN TRANSFORMER

9

176D

176D

Hammond Manufacturing

TRANSFORMER AUTO STEP UP/PLG

11

175

175

Signal Transformer

XFRMR AUTO 230/115V 750VA

0

170R

170R

Hammond Manufacturing

TRANSFORMER AUTO/LEAD CONNECTED

10

169G

169G

Hammond Manufacturing

TRANSFMR 115V TAPS 90-130V 500VA

2

Isolation Transformers and Autotransformers, Step Up, Step Down

1. Overview

Transformers are static electrical devices that transfer energy between circuits through electromagnetic induction. Isolation transformers provide galvanic separation between primary and secondary circuits, while autotransformers share a common winding. Step-up/down transformers adjust voltage levels (increasing/decreasing respectively) for power transmission, distribution, and equipment compatibility. These devices are critical in power systems, industrial machinery, renewable energy, and electronic applications.

2. Main Types and Functional Classification

TypeFunctionalityApplications
Isolation TransformerSeparates primary/secondary circuits for safety and noise reductionHospitals, data centers, laboratory equipment
AutotransformerSingle winding with shared magnetic and electrical pathVoltage regulation in industrial motors, railway systems
Step-Up TransformerIncreases voltage (N2>N1) for long-distance transmissionPower plants, grid substations
Step-Down TransformerDecreases voltage (N2<N1) for end-use compatibilityHousehold appliances, distribution networks

3. Structure and Components

Typical construction includes:

  • Core: Silicon steel laminations to reduce eddy current losses
  • Windings: Copper/aluminum coils with insulation layers (primary/secondary for isolation transformers, single tapped winding for autotransformers)
  • Insulation: Mineral oil, epoxy resin, or air-based dielectric systems
  • Enclosure: Metal housing with cooling vents or radiators
  • Terminals: Safety-rated connectors for input/output connections

4. Key Technical Specifications

ParameterSignificanceTypical Range
Turns RatioDetermines voltage transformation ratio0.1:1 to 10:1
Power RatingDefines maximum VA/kVA capacity50 VA - 100 MVA
Insulation ClassSpecifies thermal and dielectric withstand capabilityClass I/II, 150-220 C
EfficiencyEnergy conversion ratio ( = Pout/Pin)95-99% (large units)
Frequency RangeOperational frequency compatibility50/60 Hz, 400 Hz (aviation)

5. Application Areas

  • Energy: Grid transmission (step-up), distribution networks (step-down)
  • Healthcare: Isolation transformers for patient-connected medical devices
  • Manufacturing: Autotransformers for motor starting and voltage control
  • Electronics: PCB-mounted step-down transformers for AC-DC conversion
  • Renewables: Step-up transformers in solar inverters and wind turbines

6. Leading Manufacturers and Products

ManufacturerKey Products
ABBRESIBLOC dry-type transformers, 3-phase isolation units
SiemensSiempreGuard encapsulated transformers
General ElectricStep-up transformers for wind energy (110MVA/132kV)
Delta ElectronicsAutotransformers for servo motor control systems

7. Selection Guidelines

Key considerations:

  • Voltage and current requirements (including tolerance margins)
  • Isolation necessity (double insulation vs. autotransformer cost-benefit analysis)
  • Environmental factors (temperature, humidity, altitude)
  • Compliance standards (UL 5085, IEC 61558, IEEE C57.12.00)
  • Space constraints (dry-type vs. oil-immersed units)
  • Short-circuit protection requirements
Example: For medical imaging equipment, select a Class I isolation transformer with reinforced insulation and leakage current <10 A.

8. Industry Trends

Emerging developments include:

  • High-frequency transformers for compact converter systems (SiC/GaN inverters)
  • Smart transformers with integrated IoT sensors for predictive maintenance
  • Biodegradable ester-based insulation fluids
  • Amorphous core designs reducing no-load losses by 60-70%
  • Modular transformer arrays for renewable energy microgrids