Isolation Transformers and Autotransformers, Step Up, Step Down

Image Part Number Description / PDF Quantity Rfq
CV1202300

CV1202300

Hammond Manufacturing

TRANSFORMER - CONSTANT VOLTAGE

0

CV2401200

CV2401200

Hammond Manufacturing

TRANSFORMER - CONSTANT VOLTAGE

0

ICT-S-A-20

ICT-S-A-20

Signal Transformer

INDUSTRIAL CONTROL TRANSFORMER

0

ICT-S-B-20

ICT-S-B-20

Signal Transformer

INDUSTRIAL CONTROL TRANSFORMER

0

175B

175B

Hammond Manufacturing

TRANSFORMER 230 TO 115VAC 200VA

0

ICT-S-C-115

ICT-S-C-115

Signal Transformer

INDUSTRIAL CONTROL TRANSFORMER

0

175A

175A

Hammond Manufacturing

TRANSFORMER 230 TO 115VAC 100VA

0

ICT-H-C-12

ICT-H-C-12

Signal Transformer

INDUSTRIAL CONTROL TRANSFORMER

0

298D

298D

Hammond Manufacturing

TRANSFM ISOL 115 TO 230VCT 500VA

0

4500-90FW34K999

4500-90FW34K999

TE Connectivity Potter & Brumfield Relays

XFRMR NON-ISLTD AUTO 480V/277V

0

175F

175F

Hammond Manufacturing

TRANSFORMER 230 TO 115VAC 1KVA

0

PT600120

PT600120

Red Lion

XFRMR ISLTD 600V/120V

0

CV240300

CV240300

Hammond Manufacturing

TRANSFORMER - CONSTANT VOLTAGE

0

175G

175G

Hammond Manufacturing

TRANSFORMER 230 TO 115VAC 15KVA

0

CV2401800

CV2401800

Hammond Manufacturing

TRANSFORMER - CONSTANT VOLTAGE

0

ICT-S-A-16

ICT-S-A-16

Signal Transformer

INDUSTRIAL CONTROL TRANSFORMER

0

ICT-S-B-12

ICT-S-B-12

Signal Transformer

INDUSTRIAL CONTROL TRANSFORMER

0

4500-90FX28K999

4500-90FX28K999

TE Connectivity Potter & Brumfield Relays

XFRMR NON-ISLTD AUTO 480V/277V

0

ICT-H-C-16

ICT-H-C-16

Signal Transformer

INDUSTRIAL CONTROL TRANSFORMER

0

ICT-H-B-115

ICT-H-B-115

Signal Transformer

INDUSTRIAL CONTROL TRANSFORMER

0

Isolation Transformers and Autotransformers, Step Up, Step Down

1. Overview

Transformers are static electrical devices that transfer energy between circuits through electromagnetic induction. Isolation transformers provide galvanic separation between primary and secondary circuits, while autotransformers share a common winding. Step-up/down transformers adjust voltage levels (increasing/decreasing respectively) for power transmission, distribution, and equipment compatibility. These devices are critical in power systems, industrial machinery, renewable energy, and electronic applications.

2. Main Types and Functional Classification

TypeFunctionalityApplications
Isolation TransformerSeparates primary/secondary circuits for safety and noise reductionHospitals, data centers, laboratory equipment
AutotransformerSingle winding with shared magnetic and electrical pathVoltage regulation in industrial motors, railway systems
Step-Up TransformerIncreases voltage (N2>N1) for long-distance transmissionPower plants, grid substations
Step-Down TransformerDecreases voltage (N2<N1) for end-use compatibilityHousehold appliances, distribution networks

3. Structure and Components

Typical construction includes:

  • Core: Silicon steel laminations to reduce eddy current losses
  • Windings: Copper/aluminum coils with insulation layers (primary/secondary for isolation transformers, single tapped winding for autotransformers)
  • Insulation: Mineral oil, epoxy resin, or air-based dielectric systems
  • Enclosure: Metal housing with cooling vents or radiators
  • Terminals: Safety-rated connectors for input/output connections

4. Key Technical Specifications

ParameterSignificanceTypical Range
Turns RatioDetermines voltage transformation ratio0.1:1 to 10:1
Power RatingDefines maximum VA/kVA capacity50 VA - 100 MVA
Insulation ClassSpecifies thermal and dielectric withstand capabilityClass I/II, 150-220 C
EfficiencyEnergy conversion ratio ( = Pout/Pin)95-99% (large units)
Frequency RangeOperational frequency compatibility50/60 Hz, 400 Hz (aviation)

5. Application Areas

  • Energy: Grid transmission (step-up), distribution networks (step-down)
  • Healthcare: Isolation transformers for patient-connected medical devices
  • Manufacturing: Autotransformers for motor starting and voltage control
  • Electronics: PCB-mounted step-down transformers for AC-DC conversion
  • Renewables: Step-up transformers in solar inverters and wind turbines

6. Leading Manufacturers and Products

ManufacturerKey Products
ABBRESIBLOC dry-type transformers, 3-phase isolation units
SiemensSiempreGuard encapsulated transformers
General ElectricStep-up transformers for wind energy (110MVA/132kV)
Delta ElectronicsAutotransformers for servo motor control systems

7. Selection Guidelines

Key considerations:

  • Voltage and current requirements (including tolerance margins)
  • Isolation necessity (double insulation vs. autotransformer cost-benefit analysis)
  • Environmental factors (temperature, humidity, altitude)
  • Compliance standards (UL 5085, IEC 61558, IEEE C57.12.00)
  • Space constraints (dry-type vs. oil-immersed units)
  • Short-circuit protection requirements
Example: For medical imaging equipment, select a Class I isolation transformer with reinforced insulation and leakage current <10 A.

8. Industry Trends

Emerging developments include:

  • High-frequency transformers for compact converter systems (SiC/GaN inverters)
  • Smart transformers with integrated IoT sensors for predictive maintenance
  • Biodegradable ester-based insulation fluids
  • Amorphous core designs reducing no-load losses by 60-70%
  • Modular transformer arrays for renewable energy microgrids