Isolation Transformers and Autotransformers, Step Up, Step Down

Image Part Number Description / PDF Quantity Rfq
IS1800HGDV

IS1800HGDV

Tripp Lite

ISOLATOR SERIES DUAL-VOLTAGE 115

831

E5HB45S

E5HB45S

SolaHD

45KVA 480D-240DCT 80C

0

HS22F500B

HS22F500B

SolaHD

0.500KVA 240X480-24/48 BB

2

DT651H40S

DT651H40S

SolaHD

40KVA 460D-460Y SCR DRIVE

0

E81H45S

E81H45S

SolaHD

LVGP DOE2016 45KVA 480D-480Y

0

HS20F5A

HS20F5A

SolaHD

5KVA 120X240-16/32 BB

0

ES5HF25S

ES5HF25S

SolaHD

25KVA 240X480-120/240 115C

0

E79H30S

E79H30S

SolaHD

30KVA 480D-380Y

0

DT651F7.5S

DT651F7.5S

SolaHD

7.5KVA 460D-460Y SCR DRIVE

0

E2H15S

E2H15S

SolaHD

DRY DISTRN XMFR 15KVA 480D-208Y

0

DT631H75S

DT631H75S

SolaHD

75KVA 575D-230Y SCR DRIVE

0

E5H75

E5H75

SolaHD

75KVA 480D-240DCT NO ESS

0

E5HB30S

E5HB30S

SolaHD

30KVA 480D-240DCT 80C

0

E2H30S

E2H30S

SolaHD

LVGP DOE2016 30KVA 480D-208Y

0

E2HF300S

E2HF300S

SolaHD

300KVA 480D-208Y 115C

0

DT631H330S

DT631H330S

SolaHD

330KVA 575D-230Y SCR DRIVE

0

E81H150S

E81H150S

SolaHD

150KVA 480D-480Y

0

HS20B150

HS20B150

SolaHD

0.150KVA 120X240-16/32 BB

0

DT661F7.5S

DT661F7.5S

SolaHD

7.5KVA 460D-230Y SCR DRIVE

0

E5H30S

E5H30S

SolaHD

LVGP DOE2016 30KVA 480D-240DCT

0

Isolation Transformers and Autotransformers, Step Up, Step Down

1. Overview

Transformers are static electrical devices that transfer energy between circuits through electromagnetic induction. Isolation transformers provide galvanic separation between primary and secondary circuits, while autotransformers share a common winding. Step-up/down transformers adjust voltage levels (increasing/decreasing respectively) for power transmission, distribution, and equipment compatibility. These devices are critical in power systems, industrial machinery, renewable energy, and electronic applications.

2. Main Types and Functional Classification

TypeFunctionalityApplications
Isolation TransformerSeparates primary/secondary circuits for safety and noise reductionHospitals, data centers, laboratory equipment
AutotransformerSingle winding with shared magnetic and electrical pathVoltage regulation in industrial motors, railway systems
Step-Up TransformerIncreases voltage (N2>N1) for long-distance transmissionPower plants, grid substations
Step-Down TransformerDecreases voltage (N2<N1) for end-use compatibilityHousehold appliances, distribution networks

3. Structure and Components

Typical construction includes:

  • Core: Silicon steel laminations to reduce eddy current losses
  • Windings: Copper/aluminum coils with insulation layers (primary/secondary for isolation transformers, single tapped winding for autotransformers)
  • Insulation: Mineral oil, epoxy resin, or air-based dielectric systems
  • Enclosure: Metal housing with cooling vents or radiators
  • Terminals: Safety-rated connectors for input/output connections

4. Key Technical Specifications

ParameterSignificanceTypical Range
Turns RatioDetermines voltage transformation ratio0.1:1 to 10:1
Power RatingDefines maximum VA/kVA capacity50 VA - 100 MVA
Insulation ClassSpecifies thermal and dielectric withstand capabilityClass I/II, 150-220 C
EfficiencyEnergy conversion ratio ( = Pout/Pin)95-99% (large units)
Frequency RangeOperational frequency compatibility50/60 Hz, 400 Hz (aviation)

5. Application Areas

  • Energy: Grid transmission (step-up), distribution networks (step-down)
  • Healthcare: Isolation transformers for patient-connected medical devices
  • Manufacturing: Autotransformers for motor starting and voltage control
  • Electronics: PCB-mounted step-down transformers for AC-DC conversion
  • Renewables: Step-up transformers in solar inverters and wind turbines

6. Leading Manufacturers and Products

ManufacturerKey Products
ABBRESIBLOC dry-type transformers, 3-phase isolation units
SiemensSiempreGuard encapsulated transformers
General ElectricStep-up transformers for wind energy (110MVA/132kV)
Delta ElectronicsAutotransformers for servo motor control systems

7. Selection Guidelines

Key considerations:

  • Voltage and current requirements (including tolerance margins)
  • Isolation necessity (double insulation vs. autotransformer cost-benefit analysis)
  • Environmental factors (temperature, humidity, altitude)
  • Compliance standards (UL 5085, IEC 61558, IEEE C57.12.00)
  • Space constraints (dry-type vs. oil-immersed units)
  • Short-circuit protection requirements
Example: For medical imaging equipment, select a Class I isolation transformer with reinforced insulation and leakage current <10 A.

8. Industry Trends

Emerging developments include:

  • High-frequency transformers for compact converter systems (SiC/GaN inverters)
  • Smart transformers with integrated IoT sensors for predictive maintenance
  • Biodegradable ester-based insulation fluids
  • Amorphous core designs reducing no-load losses by 60-70%
  • Modular transformer arrays for renewable energy microgrids