Current Sense Transformers

Image Part Number Description / PDF Quantity Rfq
AC1015

AC1015

Talema

CURR SENSE XFMR 15A T/H

652

AC1030

AC1030

Talema

CURR SENSE XFMR 30A T/H

1304

AC1075

AC1075

Talema

CURR SENSE XFMR 75A T/H

683

AC1100

AC1100

Talema

CURR SENSE XFMR 100A T/H

895

AX-0750

AX-0750

Talema

CURR SENSE XFMR 7.5A T/H

0

AP-1500

AP-1500

Talema

CURR SENSE XFMR 10A T/H

0

ASM-010

ASM-010

Talema

CURR SENSE XFMR 10A T/H

6043

AX-1000

AX-1000

Talema

CURR SENSE XFMR 10A T/H

0

AC1200

AC1200

Talema

CURR SENSE XFMR 200A T/H

0

AS-101

AS-101

Talema

CURR SENSE XFMR 1:100 15A T/H

0

AS-104

AS-104

Talema

CURR SENSE XFMR 1:500 15A T/H

0

AZ-0500

AZ-0500

Talema

CURR SENSE XFMR 25A IN-LINE

1245

AZ-1000

AZ-1000

Talema

CURR SENSE XFMR 1000:1 50A SMD

0

ACX-1150

ACX-1150

Talema

CURR SENSE XFMR 2500:1 150A T/H

0

AC1060

AC1060

Talema

CURR SENSE XFMR 60A T/H

410

ASM-020

ASM-020

Talema

XFMR PCB +/-10% 50/60HZ 20A

0

ACX-1100

ACX-1100

Talema

CURR SENSE XFMR 2500:1 100A T/H

0

AC1005

AC1005

Talema

CURR SENSE XFMR 5A T/H

232

AC1025

AC1025

Talema

CURR SENSE XFMR 25A T/H

390

AS-103

AS-103

Talema

CURR SENSE XFMR 1:300 15A T/H

0

Current Sense Transformers

1. Overview

Current Sense Transformers (CSTs) are specialized electromagnetic devices designed to accurately detect and measure alternating current (AC) in electrical circuits. By converting primary current signals into proportional secondary currents or voltages, CSTs enable safe and reliable monitoring for control systems, energy management, and protection circuits. Their importance in modern technology spans power electronics, industrial automation, renewable energy systems, and smart grid infrastructure, where precise current measurement is critical for efficiency optimization and system safety.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Open-Circuit Core CSTLow cost, wide current range, moderate accuracySmart meters, household appliances
Closed-Loop Core CSTHigh accuracy (0.1%~0.5%), low phase errorMotor drives, precision power supplies
Hall Effect IntegrationDC/AC hybrid measurement, galvanic isolationElectric vehicle BMS, energy storage systems
High-Frequency CSTOperates >100kHz, minimized core lossWireless charging systems, induction heating
Miniature Surface-MountCompact size, PCB-mountableConsumer electronics, IoT devices

3. Structure and Components

Typical CST construction includes: - Magnetic Core: Made from ferrite, silicon steel, or nanocrystalline materials to ensure high permeability and low loss - Primary Winding: Single-turn or multi-turn conductor depending on current range - Secondary Winding: Multi-turn coil with precise turns ratio for signal scaling - Insulation System: Epoxy resin or plastic housing meeting UL/IEC dielectric standards - Termination: Screw terminals, PCB pins, or integrated connectors Advanced models incorporate shielding layers and temperature-compensated materials for enhanced stability.

4. Key Technical Specifications

ParameterTypical RangeSignificance
Current Ratio100:1 to 5000:1Determines scaling factor for measurement
Accuracy Class0.1% to 1%Critical for metering and control precision
Frequency Range50Hz-1MHzDictates application suitability
Phase Shift<1 Affects power factor calculation accuracy
Isolation Voltage2.5kV-10kVEnsures safety in high-voltage systems
Operating Temp.-40 C to +125 CEnvironmental reliability indicator

5. Application Fields

Major industries and equipment utilizing CSTs include:

  • Energy Sector: Smart grids, substation protection relays
  • Industrial Automation: Variable frequency drives, PLC systems
  • Renewable Energy: Solar inverters, wind turbine converters
  • Transportation: EV charging stations, traction control systems
  • Consumer Electronics: Smart home appliances, power banks

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
ABBACS7112kV isolation, 1% accuracy for EV charging
LEMHASS 25-SOpen-loop sensor with 120A measurement range
TE ConnectivityCurrentSense 55512Surface-mount design for PCB integration
VacuumschmelzeDIN43858High-frequency capability up to 500kHz
Allegro MicroACS37610Digital output with I C interface

7. Selection Guidelines

Key considerations for CST selection:

  1. Required current ratio and measurement range
  2. Accuracy demands (metering vs. protection applications)
  3. Environmental conditions (temperature, humidity, vibration)
  4. Frequency characteristics of the target circuit
  5. Space constraints and mounting requirements
  6. Cost-performance balance for mass production

Example: For PV inverter applications, select a closed-loop core CST with >200kHz bandwidth and IP67 rating to ensure reliable operation under fluctuating environmental conditions.

8. Industry Trends

Emerging trends shaping CST development include:

  • Integration with digital interfaces (CAN, Modbus) for smart systems
  • Wide bandgap semiconductor compatibility (SiC/GaN circuits)
  • Nano-material core adoption for reduced size and weight
  • AI-enhanced error compensation algorithms
  • Increased adoption in EV infrastructure and energy storage systems

Market forecasts indicate 8.2% CAGR through 2030, driven by renewable energy integration and industrial IoT expansion.