Current Sense Transformers

Image Part Number Description / PDF Quantity Rfq
PE-64978NL

PE-64978NL

PulseLarsen Antenna

CURR SENSE XFMR 20A T/H

245

PA1005.020QNLT

PA1005.020QNLT

PulseLarsen Antenna

XFMR CURR SENSE 1:20 AECQ SMD

0

PA1005.125QNLT

PA1005.125QNLT

PulseLarsen Antenna

XFMR CURR SENSE 1:125 AECQ SMD

0

FIS121NL

FIS121NL

PulseLarsen Antenna

CURR SENSE XFMR 1:200 15A T/H

2584

PA1005.040QNL

PA1005.040QNL

PulseLarsen Antenna

CURR SENSE XFMR 1:40 20A SMD

0

PA0368.070NL

PA0368.070NL

PulseLarsen Antenna

CURR SENSE XFMR 1:70 4A SMD

0

PE-51718NL

PE-51718NL

PulseLarsen Antenna

CURR SENSE XFMR 20A T/H

844

PE-68383NLT

PE-68383NLT

PulseLarsen Antenna

CURR SENSE XFMR 1:1:200 SMD

0

PA0368.050NLT

PA0368.050NLT

PulseLarsen Antenna

CURR SENSE XFMR 1:50 SMD

1301

PA0368.050NL

PA0368.050NL

PulseLarsen Antenna

CURR SENSE XFMR 1:50 4A SMD

1672

P0583NL

P0583NL

PulseLarsen Antenna

CURR SENSE XFMR 50:1:1 36A T/H

0

PE-68383NL

PE-68383NL

PulseLarsen Antenna

CURR SENSE XFMR 1:1:200 SMD

0

PA1005.030QNL

PA1005.030QNL

PulseLarsen Antenna

CURR SENSE XFMR 1:30 20A SMD

25

PA1005.100QNLT

PA1005.100QNLT

PulseLarsen Antenna

XFMR CURR SENSE 1:100 AECQ SMD

0

PE-51717NL

PE-51717NL

PulseLarsen Antenna

CURR SENSE XFMR 20A T/H

833

P8208NLT

P8208NLT

PulseLarsen Antenna

CURR SENSE XFMR 1:100 SMD

714

PE-51688NL

PE-51688NL

PulseLarsen Antenna

CURR SENSE XFMR 20A T/H

2072

FIS115NL

FIS115NL

PulseLarsen Antenna

CURR SENSE XFMR 1:100 25A T/H

308

PE-68210NL

PE-68210NL

PulseLarsen Antenna

CURR SENSE XFMR 1:1:50 SMD

455

PA1005.125NL

PA1005.125NL

PulseLarsen Antenna

CURR SENSE XFMR 1:125 20A SMD

2001

Current Sense Transformers

1. Overview

Current Sense Transformers (CSTs) are specialized electromagnetic devices designed to accurately detect and measure alternating current (AC) in electrical circuits. By converting primary current signals into proportional secondary currents or voltages, CSTs enable safe and reliable monitoring for control systems, energy management, and protection circuits. Their importance in modern technology spans power electronics, industrial automation, renewable energy systems, and smart grid infrastructure, where precise current measurement is critical for efficiency optimization and system safety.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Open-Circuit Core CSTLow cost, wide current range, moderate accuracySmart meters, household appliances
Closed-Loop Core CSTHigh accuracy (0.1%~0.5%), low phase errorMotor drives, precision power supplies
Hall Effect IntegrationDC/AC hybrid measurement, galvanic isolationElectric vehicle BMS, energy storage systems
High-Frequency CSTOperates >100kHz, minimized core lossWireless charging systems, induction heating
Miniature Surface-MountCompact size, PCB-mountableConsumer electronics, IoT devices

3. Structure and Components

Typical CST construction includes: - Magnetic Core: Made from ferrite, silicon steel, or nanocrystalline materials to ensure high permeability and low loss - Primary Winding: Single-turn or multi-turn conductor depending on current range - Secondary Winding: Multi-turn coil with precise turns ratio for signal scaling - Insulation System: Epoxy resin or plastic housing meeting UL/IEC dielectric standards - Termination: Screw terminals, PCB pins, or integrated connectors Advanced models incorporate shielding layers and temperature-compensated materials for enhanced stability.

4. Key Technical Specifications

ParameterTypical RangeSignificance
Current Ratio100:1 to 5000:1Determines scaling factor for measurement
Accuracy Class0.1% to 1%Critical for metering and control precision
Frequency Range50Hz-1MHzDictates application suitability
Phase Shift<1 Affects power factor calculation accuracy
Isolation Voltage2.5kV-10kVEnsures safety in high-voltage systems
Operating Temp.-40 C to +125 CEnvironmental reliability indicator

5. Application Fields

Major industries and equipment utilizing CSTs include:

  • Energy Sector: Smart grids, substation protection relays
  • Industrial Automation: Variable frequency drives, PLC systems
  • Renewable Energy: Solar inverters, wind turbine converters
  • Transportation: EV charging stations, traction control systems
  • Consumer Electronics: Smart home appliances, power banks

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
ABBACS7112kV isolation, 1% accuracy for EV charging
LEMHASS 25-SOpen-loop sensor with 120A measurement range
TE ConnectivityCurrentSense 55512Surface-mount design for PCB integration
VacuumschmelzeDIN43858High-frequency capability up to 500kHz
Allegro MicroACS37610Digital output with I C interface

7. Selection Guidelines

Key considerations for CST selection:

  1. Required current ratio and measurement range
  2. Accuracy demands (metering vs. protection applications)
  3. Environmental conditions (temperature, humidity, vibration)
  4. Frequency characteristics of the target circuit
  5. Space constraints and mounting requirements
  6. Cost-performance balance for mass production

Example: For PV inverter applications, select a closed-loop core CST with >200kHz bandwidth and IP67 rating to ensure reliable operation under fluctuating environmental conditions.

8. Industry Trends

Emerging trends shaping CST development include:

  • Integration with digital interfaces (CAN, Modbus) for smart systems
  • Wide bandgap semiconductor compatibility (SiC/GaN circuits)
  • Nano-material core adoption for reduced size and weight
  • AI-enhanced error compensation algorithms
  • Increased adoption in EV infrastructure and energy storage systems

Market forecasts indicate 8.2% CAGR through 2030, driven by renewable energy integration and industrial IoT expansion.

RFQ BOM Call Skype Email
Top