Current Sense Transformers

Image Part Number Description / PDF Quantity Rfq
TCS-07

TCS-07

Tamura

CURR SENSE XFMR 1:100 SMD

0

B78421A2105A003

B78421A2105A003

TDK EPCOS

TRANSFORMER

0

B78423P9104A5Z90

B78423P9104A5Z90

TDK EPCOS

TRANSFORMER CUSTOM

0

B78559P8037A005

B78559P8037A005

TDK EPCOS

TRANSFORMER

0

PE-68210T

PE-68210T

PulseLarsen Antenna

CURR SENSE XFMR 1:1:50 15A SMD

0

B78417A8583A3Z90

B78417A8583A3Z90

TDK EPCOS

TRANSFORMER CUSTOM

0

CR8420-100

CR8420-100

CR Magnetics, Inc.

CURR SENSE XFMR IN-LINE

0

2277239

2277239

Phoenix Contact

CURR SENSE XFMR 1250A DIN RAIL

0

PE-51719

PE-51719

PulseLarsen Antenna

CURR SENSE XFMR 20A T/H

0

PE-51686

PE-51686

PulseLarsen Antenna

CURR SENSE XFMR 20A T/H

0

B78555P9626A005

B78555P9626A005

TDK EPCOS

TRANSFORMER

0

B78446A2115A003

B78446A2115A003

TDK EPCOS

TRANSFORMER CUSTOM

0

B78545A9734A003

B78545A9734A003

TDK EPCOS

TRANSFORMER CUSTOM

0

B78520A9646A003

B78520A9646A003

TDK EPCOS

TRANSFORMER

0

H1300NLT

H1300NLT

PulseLarsen Antenna

CURR SENSE XFMR 1.414CT:1 SMD

0

B78417A8583A003

B78417A8583A003

TDK EPCOS

TRANSFORMER CUSTOM

0

B78559P8157A005

B78559P8157A005

TDK EPCOS

TRANSFORMER

0

B78529P9399A5Z90

B78529P9399A5Z90

TDK EPCOS

TRANSFORMER CUSTOM

0

B78559P9133A5N99

B78559P9133A5N99

TDK EPCOS

TRANSFORMER CUSTOM

0

B78446A2115A3Y22

B78446A2115A3Y22

TDK EPCOS

TRANSFORMER CUSTOM

0

Current Sense Transformers

1. Overview

Current Sense Transformers (CSTs) are specialized electromagnetic devices designed to accurately detect and measure alternating current (AC) in electrical circuits. By converting primary current signals into proportional secondary currents or voltages, CSTs enable safe and reliable monitoring for control systems, energy management, and protection circuits. Their importance in modern technology spans power electronics, industrial automation, renewable energy systems, and smart grid infrastructure, where precise current measurement is critical for efficiency optimization and system safety.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Open-Circuit Core CSTLow cost, wide current range, moderate accuracySmart meters, household appliances
Closed-Loop Core CSTHigh accuracy (0.1%~0.5%), low phase errorMotor drives, precision power supplies
Hall Effect IntegrationDC/AC hybrid measurement, galvanic isolationElectric vehicle BMS, energy storage systems
High-Frequency CSTOperates >100kHz, minimized core lossWireless charging systems, induction heating
Miniature Surface-MountCompact size, PCB-mountableConsumer electronics, IoT devices

3. Structure and Components

Typical CST construction includes: - Magnetic Core: Made from ferrite, silicon steel, or nanocrystalline materials to ensure high permeability and low loss - Primary Winding: Single-turn or multi-turn conductor depending on current range - Secondary Winding: Multi-turn coil with precise turns ratio for signal scaling - Insulation System: Epoxy resin or plastic housing meeting UL/IEC dielectric standards - Termination: Screw terminals, PCB pins, or integrated connectors Advanced models incorporate shielding layers and temperature-compensated materials for enhanced stability.

4. Key Technical Specifications

ParameterTypical RangeSignificance
Current Ratio100:1 to 5000:1Determines scaling factor for measurement
Accuracy Class0.1% to 1%Critical for metering and control precision
Frequency Range50Hz-1MHzDictates application suitability
Phase Shift<1 Affects power factor calculation accuracy
Isolation Voltage2.5kV-10kVEnsures safety in high-voltage systems
Operating Temp.-40 C to +125 CEnvironmental reliability indicator

5. Application Fields

Major industries and equipment utilizing CSTs include:

  • Energy Sector: Smart grids, substation protection relays
  • Industrial Automation: Variable frequency drives, PLC systems
  • Renewable Energy: Solar inverters, wind turbine converters
  • Transportation: EV charging stations, traction control systems
  • Consumer Electronics: Smart home appliances, power banks

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
ABBACS7112kV isolation, 1% accuracy for EV charging
LEMHASS 25-SOpen-loop sensor with 120A measurement range
TE ConnectivityCurrentSense 55512Surface-mount design for PCB integration
VacuumschmelzeDIN43858High-frequency capability up to 500kHz
Allegro MicroACS37610Digital output with I C interface

7. Selection Guidelines

Key considerations for CST selection:

  1. Required current ratio and measurement range
  2. Accuracy demands (metering vs. protection applications)
  3. Environmental conditions (temperature, humidity, vibration)
  4. Frequency characteristics of the target circuit
  5. Space constraints and mounting requirements
  6. Cost-performance balance for mass production

Example: For PV inverter applications, select a closed-loop core CST with >200kHz bandwidth and IP67 rating to ensure reliable operation under fluctuating environmental conditions.

8. Industry Trends

Emerging trends shaping CST development include:

  • Integration with digital interfaces (CAN, Modbus) for smart systems
  • Wide bandgap semiconductor compatibility (SiC/GaN circuits)
  • Nano-material core adoption for reduced size and weight
  • AI-enhanced error compensation algorithms
  • Increased adoption in EV infrastructure and energy storage systems

Market forecasts indicate 8.2% CAGR through 2030, driven by renewable energy integration and industrial IoT expansion.