Test Leads - Thermocouples, Temperature Probes

Image Part Number Description / PDF Quantity Rfq
5618B-6-G

5618B-6-G

Fluke Electronics

PROBE SECON. PRT 6 X 1/8 INCH OD

0

5608-12-I

5608-12-I

Fluke Electronics

PROBE SECON. PRT 100 OHM (1/8 X

0

GK18M

GK18M

TPI (Test Products International)

METER ARMOURED THERMOCOUPLE

81

TMPTRN07

TMPTRN07

Red Lion

RTD 36-1056 F

0

5627A-6-M

5627A-6-M

Fluke Electronics

PROBE RTD INDUSTRIAL 6 X 3/16 IN

0

5606-50-J

5606-50-J

Fluke Electronics

PROBE IMMERSION PRT 50MM -200 TO

0

5609-9BND-J

5609-9BND-J

Fluke Electronics

PROBE SECON. PRT 100 OHM 9IN 90

0

5609-9BND-P

5609-9BND-P

Fluke Electronics

PROBE SECON. PRT 100 OHM 9IN 90

0

5609-500-M

5609-500-M

Fluke Electronics

PROBE SECON. PRT 100 OHM (6 X 50

0

5615-12-J

5615-12-J

Fluke Electronics

PROBE SECON. PRT 100 OHM (1/4 X

0

5622-16-D

5622-16-D

Fluke Electronics

PROBE FAST RESPONSE PRT 1.6 MM D

0

5609-BEND-L

5609-BEND-L

Fluke Electronics

PROBE SECON. PRT 100 OHM BEND

0

FK25M

FK25M

TPI (Test Products International)

FLAT SENSOR BETWEEN PACK PROBE

37

5622-16-M

5622-16-M

Fluke Electronics

PROBE FAST RESPONSE PRT 1.6 MM D

0

5608-12-S

5608-12-S

Fluke Electronics

PROBE SECON. PRT 100 OHM (1/8 X

0

CK20M

CK20M

TPI (Test Products International)

1/4" PIPE CLAMP PROBE

96

5622-05-M

5622-05-M

Fluke Electronics

PROBE FAST RESPONSE PRT 0.5MM DI

0

5609-9BND-M

5609-9BND-M

Fluke Electronics

PROBE SECON. PRT 100 OHM 9IN 90

0

5611T-B

5611T-B

Fluke Electronics

PROBE BARE THERMISTOR

0

5609-20-A

5609-20-A

Fluke Electronics

PROBE SECON. PRT 100 OHM (1/4 X

0

Test Leads - Thermocouples, Temperature Probes

1. Overview

Thermocouples and temperature probes are essential components in test and measurement systems, used to convert thermal energy into electrical signals for temperature monitoring and control. Thermocouples operate based on the Seebeck effect, generating a voltage proportional to temperature differences between two dissimilar metal junctions. Temperature probes integrate sensors (e.g., thermocouples, RTDs, thermistors) with mechanical structures for specific applications. These devices are critical in industrial automation, scientific research, and quality assurance, ensuring precision in processes ranging from semiconductor manufacturing to food safety.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Thermocouples (Type J/K/T/E/R/S/B/N)Wide temperature range (-200 C to 2300 C), fast response, durabilityIndustrial furnaces, gas turbines, HVAC systems
Resistance Temperature Detectors (RTDs)High accuracy ( 0.1 C), stable long-term performancePrecision measurements in laboratories and chemical plants
Thermistor ProbesHigh sensitivity, nonlinear resistance-temperature curveMEDICAL DEVICES, battery management systems
Infrared (IR) Temperature ProbesContactless measurement, suitable for moving targetsAutomotive brake testing, electrical equipment diagnostics
Penetration ProbesSharp tips for liquid/solid material insertionFood safety inspections, soil temperature monitoring

3. Structure and Components

A typical thermocouple consists of two dissimilar metal wires (e.g., chromel-alumel for Type K) joined at a measurement junction, insulated with ceramic beads, and enclosed in a protective sheath (stainless steel or Inconel). Temperature probes integrate a sensing element (thermocouple/RTD), a probe housing (stainless steel or plastic), insulated leads, and connectors (e.g., miniature thermocouple connectors). Advanced designs include waterproof enclosures (IP67 ratings) and anti-vibration structures for harsh environments.

4. Key Technical Specifications

ParameterImportance
Temperature RangeDetermines applicability in extreme environments (e.g., cryogenics vs. molten metal)
Accuracy ( C)Impacts measurement reliability and compliance with standards (e.g., ASTM E220)
Response Time ( 63.2%)Defines speed of temperature change detection (critical for dynamic processes)
Material CompatibilityPrevents corrosion or chemical degradation in aggressive media
Electrical InsulationEnsures signal integrity and safety in high-voltage applications

5. Application Fields

Key industries include:

  • Industrial Manufacturing: Steel production, CNC machining, autoclave monitoring
  • Healthcare: Patient temperature monitoring, vaccine storage validation
  • Energy: Power plant turbine exhaust analysis, solar thermal efficiency testing
  • Research: Material science experiments, climate chamber calibration
  • Consumer Electronics: Battery thermal management, semiconductor junction testing

6. Leading Manufacturers and Representative Products

ManufacturerProduct SeriesKey Features
Fluke Calibration52II Series 0.05 C accuracy, field-replaceable probes
Omega EngineeringKJLC-18G-SSVacuum-compatible Type K thermocouples for semiconductor tools
Keysight TechnologiesU1211A4-channel thermocouple data logger with 0.2 C accuracy
TektronixCTP SeriesHigh-voltage insulated probes for power electronics testing

7. Selection Recommendations

Key considerations include:

  1. Match temperature range to application (e.g., Type R for high-temperature metallurgy)
  2. Select appropriate sensor type (RTDs for stability, thermocouples for ruggedness)
  3. Evaluate environmental factors (chemical exposure, vibration, IP rating)
  4. Ensure compatibility with measurement instruments (connector types, signal conditioning)
  5. Balance cost and longevity (e.g., sacrificial probes for corrosive processes)

8. Industry Trends

Emerging trends include:

  • Miniaturization: MEMS-based thermocouples for micro-scale thermal mapping
  • Wireless Integration: Bluetooth-enabled probes for real-time data transmission
  • Advanced Materials: Ceramic matrix composites for extreme environment durability
  • Standardization: Adoption of IEC 60584-1 for international calibration harmonization
  • Smart Probes: Embedded digital signal processing for self-diagnosis and compensation