Test Leads - Oscilloscope Probes

Image Part Number Description / PDF Quantity Rfq
P250

P250

TPI (Test Products International)

OSCOPE PROBE X100 250MHZ 100M

36

CT4202

CT4202

Cal Test Electronics

OPROBE 350MHZ 10X 1MO 1.3M 2.5MM

10

CT4205

CT4205

Cal Test Electronics

OPROBE 500MHZ 20X 1MO 1.3M 2.5MM

7

CT2593-1

CT2593-1

Cal Test Electronics

OSCOPE PROBE X20/X200 25MHZ 4M

0

6500

6500

Pomona Electronics

OSCOPE PROBE X1/X10 100MHZ 1/10M

2

GE3125

GE3125

Cal Test Electronics

OSCOPE PROBE X100 150MHZ 100M

1

PR 100A

PR 100A

B&K Precision

OSCOPE PROBE X100 250MHZ 100M

0

PP025-1

PP025-1

Teledyne LeCroy

OSCOPE PROBE X10 500MHZ 10M

0

GE3422

GE3422

Cal Test Electronics

OSCOPE PROBE X100 100MHZ 100M

0

CT2982B

CT2982B

Cal Test Electronics

OSCOPE PROBE X1K 40MHZ 100M

17

GE3225

GE3225

Cal Test Electronics

OSCOPE PROBE X100 200MHZ 100M

21

PP215

PP215

Siglent Technologies

OSCILLOSCOPE PROBE- 200 MHZ

0

VPS212-R

VPS212-R

Fluke Electronics

OSCOPE PROBE X10 200MHZ 10M

1

GE3231

GE3231

Cal Test Electronics

OSCOPE PROBE X100 200MHZ 100M

1

DL10-HCM

DL10-HCM

Teledyne LeCroy

1 GHZ 60 V COMMON MODE DIFFERENT

0

6069A

6069A

Pomona Electronics

OSCOPE PROBE X10 250MHZ 10M

1

PP009-1

PP009-1

Teledyne LeCroy

OSCOPE PROBE X10 500MHZ 10M

18

6495

6495

Pomona Electronics

OSCOPE PRB X10 100MHZ/250MHZ 10M

0

VPS510-R

VPS510-R

Fluke Electronics

OSCOPE PROBE X10 500MHZ

1

HVD3206A

HVD3206A

Teledyne LeCroy

OSCOPE PROBE X50/X500 120MHZ 10M

6

Test Leads - Oscilloscope Probes

1. Overview

Oscilloscope probes and test leads are critical interface components between electronic circuits under test and measurement instruments. They ensure accurate signal transmission while minimizing circuit loading effects. These probes convert physical electrical signals into measurable waveforms, enabling engineers to analyze voltage, current, timing, and signal integrity in real time. Their importance in modern electronics spans from R&D validation to field service diagnostics.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Passive Voltage ProbesHigh impedance (10M ), 1:1 or 10:1 attenuation, no power requiredBasic circuit troubleshooting, education labs
Active Voltage ProbesPowered design, 50k impedance, 1:1 attenuation, high bandwidth (>1GHz)High-speed digital circuits, RF testing
Current ProbesNon-invasive measurement via Hall effect or current transformerSwitching power supplies, motor drives
Differential ProbesMeasure voltage between two points, reject common-mode noiseHigh-voltage floating measurements, balanced circuits
Logic ProbesDigital signal detection with threshold indicatorsDigital circuit debugging, embedded systems

3. Structure and Components

Typical probe construction includes: - Probe tip (spring-loaded or solderable contact) - Ground lead (short/adjustable length) - Coaxial cable (50 or 75 shielded) - Compensation network (variable capacitor for frequency response adjustment) - BNC/SMA interface (50 matched connector) - Attenuation switch (for 1x/10x selection) - Probe head (ergonomic design with overvoltage protection)

4. Key Technical Specifications

ParameterDescriptionImportance
BandwidthFrequency range (-3dB point)Determines signal fidelity for high-speed transitions
Input ImpedanceResistance and capacitance presented to DUTAffects circuit loading (typically 10M //15pF)
Attenuation RatioSignal scaling factor (e.g., 10:1)Extends measurement range while maintaining impedance
Rise TimeFastest measurable edge (10-90%)Essential for digital signal analysis
Parasitic CapacitanceTip capacitance (<1pF for active probes)Impacts high-frequency measurement accuracy
CMRRCommon-mode rejection ratioCritical for differential signal integrity

5. Application Areas

  • Electronics Manufacturing (PCB testing, component validation)
  • Automotive Electronics (ECU analysis, CAN bus troubleshooting)
  • Telecommunications (5G signal analysis, fiber optic transceivers)
  • Medical Equipment (ECG machine diagnostics, imaging system validation)
  • Education & Research (University labs, prototype development)

6. Leading Manufacturers & Products

ManufacturerRepresentative ProductKey Specifications
TektronixP6139B500MHz, 10:1 passive probe, 10M impedance
KeysightN2790A2GHz active differential probe, 50k input
Flukei410scAC/DC current probe, 1500A range, 100kHz bandwidth
Rohde & SchwarzRTH-HDO441GHz bandwidth, 4-channel logic probe
SiglentSP2020200MHz passive probe, 10M , 10:1 attenuation

7. Selection Guidelines

Key considerations include: - Bandwidth matching (3-5 signal frequency) - Impedance compatibility (10M for general use, 50 for high-speed) - Signal type (voltage/current/differential) - Environmental factors (temperature, vibration) - Safety ratings (CAT II/III for industrial environments) - Cost vs. performance trade-offs

8. Industry Trends

Current trends include: - Development of 10GHz+ bandwidth active probes - Integration with AI-based signal integrity analysis - Wireless probe systems for hazardous environments - Enhanced EMI shielding for 5G/mmWave testing - Standardization of probe calibration procedures (ISO/IEC 17025) - Miniaturization for high-density PCB measurements

RFQ BOM Call Skype Email
Top