Equipment - Specialty

Image Part Number Description / PDF Quantity Rfq
601B

601B

B&K Precision

6 V & 12 V SLA BATTERYCAPACITY

7

810C

810C

B&K Precision

METER CAPACITANCE

25

889B

889B

B&K Precision

BENCH LCR/ESR METER W/COMP TESTR

5

DAS30

DAS30

B&K Precision

2 CHANNEL HS MULTI-FUNC DATA REC

2

DAS50

DAS50

B&K Precision

4 CHANNEL HS MULTI-FUNC DATA REC

0

DAS240-BAT

DAS240-BAT

B&K Precision

PORTABLE MULTI-CHANNEL RECORDER

2

DAS50-P

DAS50-P

B&K Precision

4CH HS MULTI-FUNC DATA REC W/PRI

0

DP 31A

DP 31A

B&K Precision

PULSER PROBE

16

MDL200

MDL200

B&K Precision

80V/40A/200W LOAD MODULE

29

307A

307A

B&K Precision

INSULATION CONTINUITY METER ANLG

0

DP 52

DP 52

B&K Precision

LOGIC PROBE 50MHZ

32

8614

8614

B&K Precision

DC ELECT LOAD 120V 240A 1500W

3

8514

8514

B&K Precision

DC ELECTRONIC PROGRAM LOAD 1200W

0

1211E

1211E

B&K Precision

NTSC GENERATOR HANDHELD

0

8500B

8500B

B&K Precision

DC ELEC LOAD 150V 30A 300W PROGR

20

1875

1875

B&K Precision

FREQ COUNTER 2.5GHZ HANDHELD

0

1823A

1823A

B&K Precision

FREQ COUNTER 2.4GHZ W/RATIO FUNC

0

231A

231A

B&K Precision

TESTER CABLE MULTI-NETWORK

6

308A

308A

B&K Precision

INSULATION CONTINUITY METER DGTL

0

2640

2640

B&K Precision

RF FIELD STRENGTH METER 2.0 GHZ

0

Equipment - Specialty

1. Overview

Specialty Test and Measurement Equipment refers to high-precision instruments designed for specific measurement tasks that standard equipment cannot address. These devices are critical in R&D, quality control, and failure analysis across industries. Their importance stems from enabling accurate data acquisition in complex scenarios, such as high-frequency signals, extreme environmental conditions, or nanoscale physical parameters.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Parametric AnalyzersHigh-resolution electrical parameter measurement (e.g., leakage current, capacitance)Semiconductor device characterization
Vector Network Analyzers (VNA)Frequency domain analysis of complex impedance and S-parametersRF/microwave circuit design validation
Thermal Imaging CamerasNon-contact temperature distribution measurement with IR sensorsPower electronics thermal management
Signal Integrity AnalyzersHigh-speed digital signal analysis with time-domain reflectometryPCB trace impedance testing
Material Testing MachinesMechanical property measurement under controlled stress/strainAerospace composite material evaluation

3. Structure and Components

Typical architectures include: - Sensor/transducer array with application-specific probes - Signal conditioning circuitry (amplifiers, filters) - High-speed ADC/DAC modules - FPGA-based processing units - Embedded display or interface ports (USB-C, HDMI, GPIB) - Environmental shielding (EMI/RFI protection enclosures) - Calibration hardware/software modules

4. Key Technical Specifications

ParameterDescriptionImportance
Measurement AccuracyDeviation from true value (e.g., 0.05%)Ensures reliable data for critical decisions
Frequency RangeOperational bandwidth (e.g., DC-67 GHz)Determines applicable use cases
Sampling RateData acquisition speed (e.g., 256 GS/s)Captures high-speed transient events
ResolutionSmallest detectable change (e.g., 16-bit)Enables precision in low-signal environments
Dynamic RangeSignal amplitude measurement span (e.g., 120 dB)Handles wide-ranging signal strengths

5. Application Fields

Primary industries include: - Semiconductor manufacturing (wafer-level testing) - Telecommunications (5G base station validation) - Automotive (EV battery performance analysis) - Aerospace (avionics signal integrity) - Medical devices (implantable sensor calibration) - Academic research (nanotechnology experiments)

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Specifications
Keysight TechnologiesN1062A PXIe Oscilloscope63 Gbps sampling rate, 8 channels
Teledyne LeCroyWaveMaster 8Zi-B40 GHz bandwidth, 100 GS/s
Rohde & SchwarzZNBT20 VNA9 kHz-20 GHz, 16-port configuration
Fluke Calibration729 Pressure Controller0.008% accuracy, 9 MPa range
KLA InstrumentsK-Alpha+ XPS10 nm spatial resolution, 0.1 eV energy resolution

7. Selection Recommendations

Key considerations: 1. Match measurement range/sensitivity to application needs 2. Verify compliance with industry standards (e.g., IEEE 1651 for VNAs) 3. Evaluate software ecosystem (API support, automation capabilities) 4. Consider environmental requirements (temperature stability, vibration resistance) 5. Total cost of ownership (calibration frequency, probe replacement costs) 6. Future-proofing (modular architecture, upgrade paths)

8. Industry Trends Analysis

Current trends shaping the sector: - Integration of AI/ML for predictive maintenance and anomaly detection - Miniaturization through MEMS sensor technology (e.g., handheld VNAs) - Increased adoption of O-RAN architecture driving new wireless test requirements - Quantum measurement systems entering commercial markets - Cloud-connected instruments enabling remote monitoring and data analytics - Enhanced EMI/EMC testing solutions for autonomous vehicle development

Application Case: In 5G mmWave testing, Keysight's UXM 5G Wireless Test Set combines parametric and protocol testing in a single platform, reducing validation time by 40% compared to traditional methods.

RFQ BOM Call Skype Email