Equipment - Specialty

Image Part Number Description / PDF Quantity Rfq
FLUKE-721-1601

FLUKE-721-1601

Fluke Electronics

DUAL SENSOR PRESS CALIBTR 16 PSI

0

FLUKE-714B/EN

FLUKE-714B/EN

Fluke Electronics

THERMOCOUPLE CALIBRATOR

6

GBK 130A

GBK 130A

Adam Equipment

GBK BENCH CHECKWEIGHING SCALES

20

240-127

240-127

Digilent, Inc.

DIGITAL DISCOVERY PROBE KIT

6

MM120-001633

MM120-001633

VPG Micro-Measurements

MM01-1K STUDENTDAQ

3

7602M

7602M

Krohn-Hite Corporation

WIDEBAND POWER AMPLIFIER, 34 WAT

1

PE961

PE961

Tempo Communications

ADSL SAFE PHON T SE W/2 WAY HF

0

27767

27767

Red Pitaya

LOGIC ANALYZER BASIC STEMLAB

0

DCT 201

DCT 201

Adam Equipment

WEIGH SCALE DUNE COMPACT BAL

0

CG206

CG206

FLIR Extech

COATING THICKNESS TESTER

0

HCB 5001AM

HCB 5001AM

Adam Equipment

WEIGH SCALE PORT PREC HIGHLAND

20

BKT 130A

BKT 130A

Adam Equipment

BKT LABEL PRINTING SCALE

30

GF 1320A

GF 1320A

Adam Equipment

WEIGH SCALE GF PLATFORM

20

B10465

B10465

Roving Networks / Microchip Technology

OPTOLYZER STUDIO ENTRY (WITH DON

0

NORMA 6003

NORMA 6003

Fluke Electronics

PORTABLE POWER ANALYZER WITHOUT

0

701A

701A

Teledyne LeCroy

701A VIDEO TEST GENERATOR

4

875B

875B

B&K Precision

LCR METER

11

570A

570A

B&K Precision

IC TESTER

4

IQ-200

IQ-200

Advanced Thermal Solutions, Inc.

TEMP/PRESS/VELOCITY MEASURE SYS

1

8542B

8542B

B&K Precision

DC ELEC LOAD 150V 30A 150W PROGR

4

Equipment - Specialty

1. Overview

Specialty Test and Measurement Equipment refers to high-precision instruments designed for specific measurement tasks that standard equipment cannot address. These devices are critical in R&D, quality control, and failure analysis across industries. Their importance stems from enabling accurate data acquisition in complex scenarios, such as high-frequency signals, extreme environmental conditions, or nanoscale physical parameters.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Parametric AnalyzersHigh-resolution electrical parameter measurement (e.g., leakage current, capacitance)Semiconductor device characterization
Vector Network Analyzers (VNA)Frequency domain analysis of complex impedance and S-parametersRF/microwave circuit design validation
Thermal Imaging CamerasNon-contact temperature distribution measurement with IR sensorsPower electronics thermal management
Signal Integrity AnalyzersHigh-speed digital signal analysis with time-domain reflectometryPCB trace impedance testing
Material Testing MachinesMechanical property measurement under controlled stress/strainAerospace composite material evaluation

3. Structure and Components

Typical architectures include: - Sensor/transducer array with application-specific probes - Signal conditioning circuitry (amplifiers, filters) - High-speed ADC/DAC modules - FPGA-based processing units - Embedded display or interface ports (USB-C, HDMI, GPIB) - Environmental shielding (EMI/RFI protection enclosures) - Calibration hardware/software modules

4. Key Technical Specifications

ParameterDescriptionImportance
Measurement AccuracyDeviation from true value (e.g., 0.05%)Ensures reliable data for critical decisions
Frequency RangeOperational bandwidth (e.g., DC-67 GHz)Determines applicable use cases
Sampling RateData acquisition speed (e.g., 256 GS/s)Captures high-speed transient events
ResolutionSmallest detectable change (e.g., 16-bit)Enables precision in low-signal environments
Dynamic RangeSignal amplitude measurement span (e.g., 120 dB)Handles wide-ranging signal strengths

5. Application Fields

Primary industries include: - Semiconductor manufacturing (wafer-level testing) - Telecommunications (5G base station validation) - Automotive (EV battery performance analysis) - Aerospace (avionics signal integrity) - Medical devices (implantable sensor calibration) - Academic research (nanotechnology experiments)

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Specifications
Keysight TechnologiesN1062A PXIe Oscilloscope63 Gbps sampling rate, 8 channels
Teledyne LeCroyWaveMaster 8Zi-B40 GHz bandwidth, 100 GS/s
Rohde & SchwarzZNBT20 VNA9 kHz-20 GHz, 16-port configuration
Fluke Calibration729 Pressure Controller0.008% accuracy, 9 MPa range
KLA InstrumentsK-Alpha+ XPS10 nm spatial resolution, 0.1 eV energy resolution

7. Selection Recommendations

Key considerations: 1. Match measurement range/sensitivity to application needs 2. Verify compliance with industry standards (e.g., IEEE 1651 for VNAs) 3. Evaluate software ecosystem (API support, automation capabilities) 4. Consider environmental requirements (temperature stability, vibration resistance) 5. Total cost of ownership (calibration frequency, probe replacement costs) 6. Future-proofing (modular architecture, upgrade paths)

8. Industry Trends Analysis

Current trends shaping the sector: - Integration of AI/ML for predictive maintenance and anomaly detection - Miniaturization through MEMS sensor technology (e.g., handheld VNAs) - Increased adoption of O-RAN architecture driving new wireless test requirements - Quantum measurement systems entering commercial markets - Cloud-connected instruments enabling remote monitoring and data analytics - Enhanced EMI/EMC testing solutions for autonomous vehicle development

Application Case: In 5G mmWave testing, Keysight's UXM 5G Wireless Test Set combines parametric and protocol testing in a single platform, reducing validation time by 40% compared to traditional methods.

RFQ BOM Call Skype Email