Equipment - Power Supplies (Test, Bench)

Image Part Number Description / PDF Quantity Rfq
PS/EY040R030-22

PS/EY040R030-22

XP Power

AC-DC HV PSU, 1200W, REVERSE POL

0

BOP 10-100MEL

BOP 10-100MEL

Kepco Power

POWER SUPPLY RACK MNT 1000W ETHE

10

SL100-15/208+LXI

SL100-15/208+LXI

Magna-Power Electronics

POWER SUPPLY PROGRAMED DC 1.5 KW

100

BOP 20-5DC802E

BOP 20-5DC802E

Kepco Power

POWER SUPPLY RACK MNT 100W CAPAC

10

MX180T

MX180T

AIMtti

PWR SUPP TRIPLE MULTI OUT 375W B

0

SL400-10/480+LXI

SL400-10/480+LXI

Magna-Power Electronics

POWER SUPPLY PROGRAMED DC 4 KW 0

100

Z320-1.3-LAN-U

Z320-1.3-LAN-U

TDK-Lambda, Inc.

PWR SUPPLY OUTPUT 0-320V 0-1.3A

0

SL100-80/208+LXI

SL100-80/208+LXI

Magna-Power Electronics

POWER SUPPLY PROGRAMED DC 8 KW 0

100

KLN 50-60

KLN 50-60

Kepco Power

POWER SUPPLY 3000W

10

KLN 80-180E

KLN 80-180E

Kepco Power

POWER SUPPLY 5000W SEALED LXI IN

10

KLN 100-15G

KLN 100-15G

Kepco Power

POWER SUPPLY 1500W + GPIB INTER

10

KLN 80-19

KLN 80-19

Kepco Power

POWER SUPPLY 1500W

10

ZUP3612/LU

ZUP3612/LU

TDK-Lambda, Inc.

BENCH TOP POWER SUPPLIES

0

1698B

1698B

B&K Precision

DC PWR SPLY PROGMBL 60V 3.3A

13

Z10-20-IS510-U

Z10-20-IS510-U

TDK-Lambda, Inc.

AC/DC PROGRAMMABLE SUPPLY 0-10V

0

KHX 28-53

KHX 28-53

Kepco Power

1500W POWER SUPPLY - SEALED

10

SL60-133/208+LXI

SL60-133/208+LXI

Magna-Power Electronics

POWER SUPPLY PROGRAMED DC 8 KW 0

100

BOP 72-14MG

BOP 72-14MG

Kepco Power

1000 WATT POWER SUPPLY

10

Z36-6-IS510-U

Z36-6-IS510-U

TDK-Lambda, Inc.

AC/DC PROGRAMMABLE SUPPLY 0-36V

0

PS/EY040P030-22

PS/EY040P030-22

XP Power

AC-DC HV PSU, 1200W, POSITIVE PO

0

Equipment - Power Supplies (Test, Bench)

1. Overview

Bench power supplies are adjustable DC or AC power sources designed for testing, troubleshooting, and development in electronic engineering. They provide stable, precise, and controllable electrical power to devices under test (DUTs) in laboratory, production, and field service environments. Their importance lies in ensuring product reliability, validating circuit performance, and supporting R&D workflows across industries.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Linear Power SuppliesLow noise, high stability, fast transient responseLaboratory testing of analog circuits
Switching Power SuppliesHigh efficiency (>80%), wide input range, compact sizeAutomated production line testing
Programmable Power SuppliesComputer-controlled output, waveform generation, data loggingAutomotive electronics validation
Multi-channel Power SuppliesIndependent voltage/current control for multiple outputsTesting IoT devices with multiple rails

3. Structure and Components

Typical bench power supplies include:

  • Metallic enclosure with ventilation slots
  • AC/DC power module (linear/regenerative topology)
  • Control panel with digital/analog interfaces
  • Output terminals (banana jacks, binding posts)
  • Active cooling system (fan/heat sink)
  • Communication ports (USB/LAN/GPIB)

4. Key Technical Specifications

ParameterDescriptionImportance
Output Voltage Range0-200V (single/multi-range options)Determines compatibility with DUT requirements
Current Resolution1mA-10 A precisionImpacts test accuracy for low-power devices
Load Regulation<0.01% change under varying loadEnsures stable output during dynamic testing
Ripple & Noise<3mVpp @ 20MHz bandwidthCritical for sensitive analog circuit testing
Transient Response Time10-100 s recovery timeMeasures stability during sudden load changes

5. Application Fields

  • Electronics manufacturing (IC testing, PCB validation)
  • Telecom equipment (5G base station power simulation)
  • Automotive R&D (ECU power cycling tests)
  • Aerospace (avionics power quality analysis)
  • Educational labs (student project prototyping)

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN6700 Modular Power SystemHot-swappable modules, 16-bit resolution
Teledyne LeCroyTS-8080800W regenerative AC/DC source
Siglent TechnologiesSPD1168X16-bit touchscreen control, list mode
Chroma Systems62000P SeriesGrid simulation, energy recovery

7. Selection Recommendations

Key considerations:

  • Match output specs to DUT's maximum power requirements
  • Choose appropriate control interface (analog/digital)
  • Assess thermal management needs for continuous operation
  • Prioritize calibration features for traceable measurements

Example: For battery simulation applications, select a bidirectional power supply with dynamic profiling capabilities.

8. Industry Trends

Current development trends include:

  • Integration of AI-based predictive maintenance
  • Higher power density (3-5W/cm ) through GaN technology
  • Adoption of PMBus for smart power system management
  • Expansion of 800V DC test capabilities for EV applications
  • Cloud-connected power supplies for remote monitoring

RFQ BOM Call Skype Email