Equipment - Oscilloscopes

Image Part Number Description / PDF Quantity Rfq
2563

2563

B&K Precision

70MHZ, 2 GSA/S 4 CHANNEL DIGITAL

2

2512

2512

B&K Precision

100MHZ HANDHELD DIG OSCOPE

5

2553

2553

B&K Precision

70 MHZ 2 GSA/S 4 CH DSO

2

2530

2530

B&K Precision

OSCOPE 25MHZ DIGITAL STORAGE

0

2516

2516

B&K Precision

100MHZ ISLTD HANDHELD DIG OSCOPE

3

2563-MSO

2563-MSO

B&K Precision

70MHZ, 2 GSA/S 4 CHANNEL MIXED S

1

2565

2565

B&K Precision

100 MHZ, 2 GSA/S 4 CHANNEL DIGIT

1

2515

2515

B&K Precision

60MHZ ISLTD HANDHELD DIG OSCOP

2

2544C

2544C

B&K Precision

200 MHZ, 1 GSA/S 2 CHANNEL DIGIT

1

2544C-MSO

2544C-MSO

B&K Precision

200 MHZ, 1 GSA/S 2 CHANNEL MIXED

2

2120C

2120C

B&K Precision

30 MHZ ANALOG OSCILLOSCOPE

0

2121C

2121C

B&K Precision

30 MHZ ANALOG OSCILLOSCOPE W/COU

0

2160C

2160C

B&K Precision

60 MHZ ANALOG OSCILLOSCOPE

0

2568-MSO

2568-MSO

B&K Precision

300 MHZ, 2 GSA/S 2 CHANNEL MIXED

0

2566-MSO

2566-MSO

B&K Precision

200 MHZ, 2 GSA/S 2 CHANNEL MIXED

0

2160A

2160A

B&K Precision

O'SCOPE 60MHZ DUAL TR/DLY SWEEP

0

2190D

2190D

B&K Precision

100MHZ DIG STORAGE OSCILLOSCOPE

0

2190B

2190B

B&K Precision

OSCILLOSCOPE 100MHZ

0

2120B

2120B

B&K Precision

O'SCOPE 30MHZ DUAL TRACE

0

2556

2556

B&K Precision

200 MHZ 2 GSA/S 2 CH DSO

0

Equipment - Oscilloscopes

1. Overview

Oscilloscopes are electronic test instruments that graphically display varying signal voltages over time. As fundamental tools in electrical engineering, they enable visualization of waveform shapes, signal integrity analysis, and transient event detection. Modern oscilloscopes combine analog signal acquisition with digital processing to support complex measurements in R&D, manufacturing, and field service applications.

2. Main Types and Functional Classification

TypeKey FeaturesApplications
Analog OscilloscopesContinuous signal display using CRT technology, real-time waveform representationBasic signal observation in education and legacy systems
Digital Storage Oscilloscopes (DSO)Digitized waveform storage, advanced triggering, FFT analysisPCB debugging, power electronics analysis
Mixed Signal Oscilloscopes (MSO)Combines analog/digital channels, protocol decoding (I2C, SPI)Embedded system development, FPGA testing
Portable OscilloscopesBattery-powered, rugged design, USB/LAN connectivityField maintenance, industrial troubleshooting
High-Performance OscilloscopesMulti-GHz bandwidth, deep memory, differential probing5G communication testing, high-speed serial buses

3. Structure and Components

Typical oscilloscope architecture includes: - Display Unit: LCD/TFT screen with measurement annotations - Vertical System: Attenuators and amplifiers for signal scaling - Trigger System: Synchronization circuitry for waveform stability - Data Acquisition: ADC converters (8-16 bit resolution) - Processing Unit: FPGA/DSP for waveform analysis - Connectivity Ports: USB, Ethernet, GPIB for data transfer

4. Key Technical Specifications

ParameterDescriptionImportance
BandwidthFrequency range (-3dB point)Determines maximum measurable signal frequency
Sample RateSamples per second (MS/s, GS/s)Affects timing resolution and aliasing prevention
Vertical ResolutionADC bit depthInfluences amplitude measurement accuracy
Memory DepthWaveform storage capacityEnables long-duration signal capture at high sampling rates
Rise TimeFastest detectable transition speedCritical for digital signal edge analysis

5. Application Fields

  • Electronics Manufacturing: PCB fault diagnosis using signal integrity analysis
  • Telecommunications: 5G NR signal measurement with 800MHz+ bandwidth scopes
  • Automotive: CAN bus protocol decoding in ECU development
  • Academia: Student laboratory signal characterization
  • Aerospace: Avionics signal verification under MIL-STD standards

6. Leading Manufacturers and Products

ManufacturerKey Product SeriesSpecifications
Keysight TechnologiesInfiniium MXR-Series500MHz-8GHz bandwidth, 10-bit resolution
Teledyne LeCroyWaveMaster 8Zi-B4GHz bandwidth, 20GS/s sampling rate
Rohde & SchwarzRTO66GHz bandwidth, 15-bit vertical resolution
FlukeScopeMeter 190-502500MHz, CAT IV 600V safety rating
NI (National Instruments)SCOPE PXIe-51861GHz bandwidth, 15GS/s with FPGA processing

7. Selection Guidelines

Key considerations include: - Bandwidth requirement (5 target signal frequency) - Channel count (4 analog + 16 digital for MSO applications) - Sampling rate ( 2 bandwidth for accurate reconstruction) - Probing compatibility (differential/single-ended, voltage range) - Software features (mask testing, compliance automation) - Budget constraints (entry-level: $1k-$5k, high-end: $50k+)

8. Industry Trends

Emerging developments include: - Integration of AI/ML for anomaly detection in signal patterns - Modular oscilloscopes with customizable FPGA processing - Real-time spectrum analysis combining time/frequency domains - USB-powered pocket scopes with smartphone integration - Enhanced protocol decoding support for emerging standards (PCIe 6.0, USB4)

RFQ BOM Call Skype Email
Top