Equipment - Electrical Testers, Current Probes

Image Part Number Description / PDF Quantity Rfq
MA620

MA620

FLIR Extech

CLAMP METER, TRMS + NCV, 600A AC

0

MA640

MA640

FLIR Extech

CLAMP METER, AC/DC + NCV, 600A

0

MA410T

MA410T

FLIR Extech

400A AC TRUE RMS CLAMP METER + N

0

RT30

RT30

FLIR Extech

WIRELESS CIRCUIT IDENTIFIER, 915

0

MA640-K

MA640-K

FLIR Extech

PHASE ROTATION/CLAMP METER KIT

0

DV26

DV26

FLIR Extech

CAT IV VOLTAGE DETECTOR, AC, NON

0

MA220

MA220

FLIR Extech

CLAMP METER, AC/DC

0

EX730

EX730

FLIR Extech

CLAMP METER, AC/DC, TRMS 800A

0

DV40

DV40

FLIR Extech

VOLTAGE DETECTOR NON-CONTACT W/I

0

MA620-K

MA620-K

FLIR Extech

INDUSTRIAL DMM/CLAMP METER TEST

0

38387-NIST

38387-NIST

FLIR Extech

AMMETER W/NIST CERTIFICATE 38387

0

382075-NIST

382075-NIST

FLIR Extech

POWER CLAMP METER W/NIST 382075

0

MA150-NIST

MA150-NIST

FLIR Extech

CLAMP METER WITH NIST, MA150

0

MA220-NIST

MA220-NIST

FLIR Extech

CLAMP METER WITH NIST MA220

0

MA160-NIST

MA160-NIST

FLIR Extech

CLAMP METER OPEN JAW TRUE RMS 20

0

EX710

EX710

FLIR Extech

CLAMP METER, AC, 800A

0

MA620-NIST

MA620-NIST

FLIR Extech

CLAMP METER WITH NIST, MA620

0

MA435T-NIST

MA435T-NIST

FLIR Extech

400A TRUE RMS AC/DC CLAMP METER

0

CB20

CB20

FLIR Extech

CIRCUIT BREAKER FINDER/RECEPTACL

0

MA430-NIST

MA430-NIST

FLIR Extech

400A TRUE RMS AC CLAMP METER WIT

0

Equipment - Electrical Testers, Current Probes

1. Overview

Electrical testers and current probes are essential tools for measuring, analyzing, and troubleshooting electrical systems. They enable precise quantification of parameters like voltage, current, resistance, and power quality. These devices play a critical role in ensuring safety, efficiency, and reliability in industries such as power generation, electronics manufacturing, automotive engineering, and renewable energy systems.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
MultimetersMeasures voltage, current, resistance, and continuity; available in digital and analog variantsGeneral electronics troubleshooting
Clamp MetersNon-contact current measurement using jaw clamp; measures AC/DC currentIndustrial motor maintenance
Insulation Resistance TestersHigh-voltage resistance testing for insulation integrityElectrical safety compliance checks
Current ProbesAttaches to oscilloscopes for current waveform analysis; types include Hall Effect and current transformersPower supply design validation
Power Quality AnalyzersMeasures harmonics, flicker, and transient disturbancesGrid stability assessment

3. Structure and Components

Typical electrical testers consist of: - Measurement Circuitry: Precision sensors (e.g., shunt resistors, Hall sensors) and signal conditioning modules. - Display Interface: LCD/OLED screens with digital readouts or waveform visualization. - Input Probes: Insulated test leads, clamp jaws, or specialized probes for specific parameters. - Power Supply: Battery or AC-powered systems with safety isolation. Current probes utilize magnetic core assemblies (for AC coupling) or Hall Effect sensors (for DC measurement) integrated with coaxial cables for oscilloscope connectivity.

4. Key Technical Specifications

ParameterDescriptionImportance
Measurement RangeSpan of measurable values (e.g., 0-1000 A)Determines applicability to specific loads
AccuracyError margin (e.g., 0.5%)Ensures reliable data for critical systems
Frequency ResponseBandwidth for AC measurements (e.g., 20 Hz 100 kHz)Affects waveform fidelity in power electronics
ResolutionSmallest detectable change (e.g., 0.1 mA)Enables precise low-current analysis
Isolation VoltageMaximum voltage separation between circuit and groundEnsures user safety in high-voltage environments

5. Application Fields

Key industries include: - Power Utilities: Grid maintenance using insulation testers and power quality analyzers. - Electronics Manufacturing: PCB testing with multimeters and current probes. - Automotive: Electric vehicle battery and motor testing. - Aerospace: Avionics system integrity checks. - Renewables: Solar inverter efficiency validation. Example: Using clamp meters to detect overload conditions in industrial conveyor belt systems.

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
FlukeFluke 434 II SeriesPower quality analyzer with energy logging
Keysight TechnologiesN2820A High-Sensitivity ProbeMeasures currents as low as 1 mA
Teledyne LeCroyCP030A Current Probe30 MHz bandwidth for switching power supplies
MeggerMegger MIT400Insulation tester with 10 kV output

7. Selection Guidelines

Consider: 1. Application Requirements: AC/DC measurement needs, voltage levels. 2. Accuracy vs. Cost: High-precision models for R&D vs. basic tools for fieldwork. 3. Environmental Factors: Temperature range, waterproof ratings. 4. Compatibility: Probe interface match with oscilloscopes or DAQ systems. 5. Safety Ratings: CAT IV certification for industrial environments.

8. Industry Trends

Emerging trends include: - Wireless Connectivity: Bluetooth-enabled testers for real-time data logging. - AI Integration: Automated fault diagnosis via machine learning. - Miniaturization: Chip-based current sensors for embedded systems. - Wide Bandgap Compatibility: Probes optimized for SiC/GaN power devices. - Energy Efficiency: Low-power designs for extended battery life. Example: IoT-enabled clamp meters for predictive maintenance in smart factories.

RFQ BOM Call Skype Email