Accessories

Image Part Number Description / PDF Quantity Rfq
WS510-FP-GERMAN

WS510-FP-GERMAN

Teledyne LeCroy

WS510 GERMAN FRONT PANEL OVERLAY

0

589203003

589203003

Teledyne LeCroy

WVSRFR,WAVEJET,HDO EURO PWR CRD

0

WS510-SPECTRUM

WS510-SPECTRUM

Teledyne LeCroy

SPECTRUM ANALYSIS OPTION FOR WAV

0

589202102

589202102

Teledyne LeCroy

ARBSTUDIO US POWER CORD

0

DA18XX-P01

DA18XX-P01

Teledyne LeCroy

WAVESTATION US POWER CORD

0

WS510-DIGRFV4BUS D

WS510-DIGRFV4BUS D

Teledyne LeCroy

DIGRF V4 BUS DECODE OPTION FOR W

0

HDA-DLS-18QL

HDA-DLS-18QL

Teledyne LeCroy

18 CHANNEL QUICKLINK LEADSET FOR

0

WS510-CAN FDBUS TD

WS510-CAN FDBUS TD

Teledyne LeCroy

CAN AND CAN FD TRIGGER AND DECOD

0

WS10-SOFTCASE

WS10-SOFTCASE

Teledyne LeCroy

WS10 SOFT CARRYING CASE

0

42A0000001510

42A0000001510

Teledyne LeCroy

WVAC 1X2,2X2,1XX2,1X1 US PWR CRD

0

WS510-CANBUS TD

WS510-CANBUS TD

Teledyne LeCroy

CAN TRIGGER AND DECODE OPTION FO

0

WS510-LINBUS TD

WS510-LINBUS TD

Teledyne LeCroy

LIN BUS TRIGGER & DECODE OPTION

0

WS510-USB2-HSICBUS D

WS510-USB2-HSICBUS D

Teledyne LeCroy

USB 2.0 HSIC DECODE OPTION FOR W

0

WS510-UART-RS232BUS TD

WS510-UART-RS232BUS TD

Teledyne LeCroy

UART AND RS232 BUS TRIGGER AND D

0

WJT-RACK

WJT-RACK

Teledyne LeCroy

RACKMOUNT KIT FOR WAVEJET TOUCH

0

WS510-FLEXRAYBUS TD

WS510-FLEXRAYBUS TD

Teledyne LeCroy

FLEXRAY TRIGGER AND DECODE OPTIO

0

WJ-RACK

WJ-RACK

Teledyne LeCroy

KIT 5U RACKMOUNT FOR WAVEJET

0

HDO4K-RHD

HDO4K-RHD

Teledyne LeCroy

REMOVABLE HARD DRIVE PKG

0

WS10-HARDCASE

WS10-HARDCASE

Teledyne LeCroy

WS10 HARD CARRYING CASE

0

WS510-HARDCASE

WS510-HARDCASE

Teledyne LeCroy

WS510 HARD CARRYING CASE

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top