Accessories

Image Part Number Description / PDF Quantity Rfq
69131

69131

Klein Tools

BULB FOR CONTINUITY TESTER

4

VDV770-080

VDV770-080

Klein Tools

VDV SCOUT PRO SERIES CARRYING CA

0

VDV999-065

VDV999-065

Klein Tools

PROBEPLUS TIP

1

69193

69193

Klein Tools

MM100 FUSE KIT

2

VDV999-067

VDV999-067

Klein Tools

TRACEALL LEADS

1

VDV999-109

VDV999-109

Klein Tools

VDV SCOUT PRO SELF-STORING REMOT

4

VDV770-500

VDV770-500

Klein Tools

TONE AND PROBE PRO ZIP CASE

6

69411

69411

Klein Tools

CIRCUIT BREAKER FINDER ACCESSORY

29

VDV999-059

VDV999-059

Klein Tools

TRACEALL PROBE TIP

12

69409

69409

Klein Tools

LINE SPLITTER 10X

23

VDV512-110

VDV512-110

Klein Tools

COAX EXPLORER 2 REMOTE KIT

16

69146

69146

Klein Tools

ADAPTER FROM TYPE K TO BANANA PL

0

69194

69194

Klein Tools

MM200 FUSE KIT

8

VDV999-150

VDV999-150

Klein Tools

REPLACEMENT REMOTE FOR LAN EXPLO

5

69190

69190

Klein Tools

MAGNETIC HANGER

15

VDV726-125

VDV726-125

Klein Tools

JUMPER CABLE FOR TEST-N-MAP REMO

3

69417

69417

Klein Tools

MAGNETIC HANGER

0

VDV999-068

VDV999-068

Klein Tools

REPLACEMENT PROBE TIP FOR PROVE-

3

VDV526-055

VDV526-055

Klein Tools

LANMAP KIT FOR VDV SCOUT PRO TES

8

VDV501-210

VDV501-210

Klein Tools

SELF-STORING TEST + MAPTM REMOTE

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top