Accessories

Image Part Number Description / PDF Quantity Rfq
PM9080/101

PM9080/101

Fluke Electronics

ADAPTER OPTICAL TO RS232 OPTICAL

0

4112723

4112723

Fluke Electronics

SILVERCAREPLAN-GROUP1-5YR

0

884X-SHORT

884X-SHORT

Fluke Electronics

4 WIRE SHORT

6

4112706

4112706

Fluke Electronics

SILVERCAREPLAN-GROUP1-3YR

0

TRM50

TRM50

Fluke Electronics

FEED THROUGH BNC TERMINATOR

1

CAMO-C25/WL

CAMO-C25/WL

Fluke Electronics

CASE CAMO WDLND 8.75"X5.5"X2.5"

3

884X-USB

884X-USB

Fluke Electronics

CABLE ADAPTER USB TO RS232

0

FLUKE-700BCW

FLUKE-700BCW

Fluke Electronics

BAR CODE WAND

0

STL120-III

STL120-III

Fluke Electronics

SHIELDED TEST LEAD SET 12.5MHZ 1

0

BHT190

BHT190

Fluke Electronics

BUS HEALTH TEST ADAPTER DB-9 AND

0

9310

9310

Fluke Electronics

CASE MICRO-BATH CARRYING (6102)

0

CABLE REEL 25M BL

CABLE REEL 25M BL

Fluke Electronics

FLUKE-1623-2/1625-2 25M BLUE

0

CABLE REEL 25M GR

CABLE REEL 25M GR

Fluke Electronics

FLUKE-1623-2/1625-2 25M GREEN

0

CAMO-C25/FO

CAMO-C25/FO

Fluke Electronics

CASE FOREST CAMO 8.75"X5.5"X2.5"

1

FLK-LENS/25MAC2

FLK-LENS/25MAC2

Fluke Electronics

INFRARED MACRO LENS

2

CC-5

CC-5

Fluke Electronics

1 X CARRYING CASE WITH MAGNET

0

FLK-050-CLKT

FLK-050-CLKT

Fluke Electronics

2" C-RANGE IR WINDOW KWIK TWIST

0

2085

2085

Fluke Electronics

COVER PLASTIC BLANK ACCESS (7103

0

CS20MA

CS20MA

Fluke Electronics

CURRENT SHUNT 4-20MA

0

2687555

2687555

Fluke Electronics

IR SMART BATTERY PACK

13

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top