Accessories

Image Part Number Description / PDF Quantity Rfq
2638/CASE

2638/CASE

Fluke Electronics

TRANSIT CASE

0

1586-CASE

1586-CASE

Fluke Electronics

CASE CARRYING 1586A

0

9170-INSD

9170-INSD

Fluke Electronics

INSERT D 9170 METRIC MISC HLS

0

MA190

MA190

Fluke Electronics

KIT ACCESSORY FOR MEDICAL/VIDEO

0

3141-3

3141-3

Fluke Electronics

INSERT B AL-BRNZ W/ CMPRSN HOLES

0

FVF-SC5

FVF-SC5

Fluke Electronics

FLUKEVIEW FORMS BASIC 8845/8846

0

FLUKE-1750/SITE-L

FLUKE-1750/SITE-L

Fluke Electronics

1 SITE LICENSE FOR FLUKE-1750 PW

0

9170-CASE

9170-CASE

Fluke Electronics

CASE 9170-3 CARRYING

0

P5514SK

P5514SK

Fluke Electronics

SEAL KIT P5514

0

1586-2586-KIT

1586-2586-KIT

Fluke Electronics

MODULE HI-CAPACITY MODULE WITH R

0

9142-INSZ

9142-INSZ

Fluke Electronics

INSERT BLANK 9142

0

3102-7

3102-7

Fluke Electronics

INSERT AL 7/16IN (9102 9009)

0

1586-2586/C

1586-2586/C

Fluke Electronics

MODULE (ONLY) HI-CAPACITY MODULE

0

TPS SHUNT 20MA

TPS SHUNT 20MA

Fluke Electronics

A680501057 SHUNT 20 MA AC/DC

0

Y200F

Y200F

Fluke Electronics

KIT FULL-RACK MOUNT

0

3102-2

3102-2

Fluke Electronics

INSERT AL 1/8IN (9102 9009)

0

S2P-TI/R-125

S2P-TI/R-125

Fluke Electronics

SILVER CAREPLAN TI125 TIR125 2 Y

0

FLUKE-700M20TH

FLUKE-700M20TH

Fluke Electronics

PREMIUM M20 PRESS TEST HOSE

0

S3P-TI/R-29

S3P-TI/R-29

Fluke Electronics

SILVER CAREPLAN TI29 TIR29 3 YR

0

9190-INSE

9190-INSE

Fluke Electronics

INSERT E 9190 METRIC 0.25 IN REF

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top