Accessories

Image Part Number Description / PDF Quantity Rfq
810QDC

810QDC

Fluke Electronics

810QDC QUICK DISCONNECT CABLE

0

9173-INSZ

9173-INSZ

Fluke Electronics

INSERT BLANK 9173

0

FVF-SC4

FVF-SC4

Fluke Electronics

FLUKEVIW FRM W/CBL FOR 8845/8846

0

FLUKE-CO-205

FLUKE-CO-205

Fluke Electronics

CARBON MONOXIDE ASPIRATOR KIT

0

CWS3111-KGCM2

CWS3111-KGCM2

Fluke Electronics

CONVERSION WEIGHT SET P3111/P321

0

FLUKE-830/SHIMS

FLUKE-830/SHIMS

Fluke Electronics

PRECISION SHIM KIT SIZES A-B MET

0

P5531-3.5M

P5531-3.5M

Fluke Electronics

DIRT/MOISTURE TRAP 3.5 MPA (500

0

4112714

4112714

Fluke Electronics

SILVERCAREPLAN-GROUP1-4YR

0

S2P-TI/R-27

S2P-TI/R-27

Fluke Electronics

SILVER CAREPLAN TI27 TIR27 2 YR

0

TQSOFT-IQ/OQ

TQSOFT-IQ/OQ

Fluke Electronics

SOFTWARE TQSOFT W/ IQ/OQ

0

S2P-TIX520

S2P-TIX520

Fluke Electronics

SILVER CAREPLAN TIX520 2 YR

0

9190-INSF

9190-INSF

Fluke Electronics

INSERT F 9190 METRIC 0.25 IN REF

0

1586-2588

1586-2588

Fluke Electronics

MODULE (ONLY) DAQ-STAQ MODULE W/

0

SCP-TI100

SCP-TI100

Fluke Electronics

SILVER CAREPLAN TI100 1 YR

0

Y1586D

Y1586D

Fluke Electronics

RACK MOUNT KIT DUAL (FULL RACK)

0

CASE-2270

CASE-2270

Fluke Electronics

REUSABLE TRANSIT CASE FOR 227X

0

2362-156

2362-156

Fluke Electronics

ADAPTER SPARE AC 15V (1529) 110V

0

9144-INSB

9144-INSB

Fluke Electronics

INSERT B 9144 CMP HLS

0

FLUKE-CV200

FLUKE-CV200

Fluke Electronics

2" IR WINDOW HAND DOOR LATCH

3

CWS3830-PSI

CWS3830-PSI

Fluke Electronics

CONVERSION WEIGHT SET P3830 PSI

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top