Accessories

Image Part Number Description / PDF Quantity Rfq
NORMA 150A SHUNT

NORMA 150A SHUNT

Fluke Electronics

EXTERNAL SHUNT WITH CABLES

0

1551-CBL

1551-CBL

Fluke Electronics

CABLE RS-232 155X

0

3150-2

3150-2

Fluke Electronics

INSERT A ALUMINA W/ MISC HOLES (

0

525A/CASE

525A/CASE

Fluke Electronics

TRANSIT CASE

0

FLUKE-700MTH

FLUKE-700MTH

Fluke Electronics

PREMIUM METRIC PRESS TEST HOSE

0

P5522SK

P5522SK

Fluke Electronics

SEAL KIT P5522

0

S3P-TI95-9HZ

S3P-TI95-9HZ

Fluke Electronics

SILVER CAREPLAN TI95 3 YR

0

ES-162P4

ES-162P4

Fluke Electronics

KIT STAKE 4-POLE

0

CWS3111-PSI

CWS3111-PSI

Fluke Electronics

CONVERSION WEIGHT SET P3111/P321

0

FLK 2X LENS

FLK 2X LENS

Fluke Electronics

INFRARED TELEPHOTO LENS (2X MAG)

0

FLK-TIX5XX-HDMI

FLK-TIX5XX-HDMI

Fluke Electronics

HDMI CABLE

0

2383-1

2383-1

Fluke Electronics

CABLE SERIAL TO USB CONVERTER

0

FLUKE-17XX AUX

FLUKE-17XX AUX

Fluke Electronics

AUXILIARY INPUT ADAPTER 17XX

0

P5543

P5543

Fluke Electronics

ANGLE ADAPTER

0

4112684

4112684

Fluke Electronics

GOLDCAREPLAN-GROUP1-4YR

0

PRESSCAL

PRESSCAL

Fluke Electronics

PRESSCAL SOFTWARE (IMPROVED ACCU

0

FLUKE-N4K RACK KIT

FLUKE-N4K RACK KIT

Fluke Electronics

N4K 19 INCH RACK MOUNT KIT W/HAN

0

CWS3111-KPA

CWS3111-KPA

Fluke Electronics

CONVERSION WEIGHT SET P3111/P321

0

FLUKE-750SW UPG

FLUKE-750SW UPG

Fluke Electronics

DPCTRACK2 UPG

0

GEOX PROBE CABLE

GEOX PROBE CABLE

Fluke Electronics

CONN CBL GEOX FOR SELECTIVE CLMP

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top