Accessories

Image Part Number Description / PDF Quantity Rfq
CT3978

CT3978

Cal Test Electronics

PROBE BODY FIXED TIP KIT W/FULL

1

CTM-8681-9

CTM-8681-9

Cal Test Electronics

INSULATOR FOR TELCOM CLIPS WHITE

0

CT3723

CT3723

Cal Test Electronics

POWER ADAPTER 9 V DC 600MA 2.1MM

31

CT2712A-8

CT2712A-8

Cal Test Electronics

TIP INSULATOR GRAY 5MM

238

CTM-29-0

CTM-29-0

Cal Test Electronics

GENERAL PURPOSE/GEOPHONE INSULAT

40

CTM-62-0

CTM-62-0

Cal Test Electronics

ALLIGATOR INSULATOR VINYL BLACK

0

CT3197B

CT3197B

Cal Test Electronics

IMPEDANCE CONVERTER SET IMPROVED

5

CTM-8681-0

CTM-8681-0

Cal Test Electronics

INSULATOR FOR TELCOM CLIPS BLACK

498

CT3978B

CT3978B

Cal Test Electronics

PROBE BODY LOCK CAP ACCY UL B/R

25

CT2663

CT2663

Cal Test Electronics

INSULATED SPLICE, 4MM J - PAIR B

19

CT4140A-0.5A

CT4140A-0.5A

Cal Test Electronics

4MM INLINE FUSE ADAPTER, 1KV CAT

15

CT3646-8

CT3646-8

Cal Test Electronics

ATTENUATOR TIP COVER GRAY 3.5MM

3

CT2248-0

CT2248-0

Cal Test Electronics

INSULATED SPLICE, 4MM J - BLACK

2

CT2710-12-0

CT2710-12-0

Cal Test Electronics

GROUND LEAD W/MINI-ALLIGATOR, 12

105

CTM-62-2

CTM-62-2

Cal Test Electronics

ALLIGATOR INSULATOR VINYL RED

17

CT2248-2

CT2248-2

Cal Test Electronics

INSULATED SPLICE, 4MM J - RED

1

CT4140A-2.0A

CT4140A-2.0A

Cal Test Electronics

4MM INLINE FUSE ADAPTER, 1KV CAT

12

CTM-26-2

CTM-26-2

Cal Test Electronics

HEAVY DUTY & AUTOMOTIVE CLIP INS

168

CT3652-8

CT3652-8

Cal Test Electronics

COVER SHELL 3.5MM GRAY W/SLIPON

67

CT3195

CT3195

Cal Test Electronics

FUSE 660V 500MA 30KA 6 X 32MM CE

24

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email