Accessories

Image Part Number Description / PDF Quantity Rfq
TL 120

TL 120

B&K Precision

MODULAR TEST LEAD PAIR

0

LC 28A

LC 28A

B&K Precision

METER CARRYING CASE

0

AN 302

AN 302

B&K Precision

DIPOLE ANTENNA 1.25 TO 1.65GHZ

0

760PH

760PH

B&K Precision

PH PROBE FOR MODEL 760

0

760CP

760CP

B&K Precision

CONDUCTIVITY PROBE 760

0

TP-A

TP-A

B&K Precision

DMM ACCESSORY

0

BC 885 EXD

BC 885 EXD

B&K Precision

230V AC ADAPTER

0

LC 760

LC 760

B&K Precision

ALUM CASE W/FOAM PADDING

0

AD 26

AD 26

B&K Precision

CONN SMAJ TO BNC MALE 2650/2658

0

HU116

HU116

B&K Precision

UVA SENSOR

0

LC760

LC760

B&K Precision

CARRYING CASE FOR MODEL 760DX

0

CR-23

CR-23

B&K Precision

ADAPTER CRT TUBE TO 480 RESTORER

0

BC 2650

BC 2650

B&K Precision

120V, 60HZ AC ADAPTER

0

CC540

CC540

B&K Precision

GENERAL PURPOSE OSCOPE ADPT KIT

0

CR XA

CR XA

B&K Precision

UNIVERSAL ADAPTER

0

TL310

TL310

B&K Precision

REPL TEST LEAD MODEL 310

0

760DOP

760DOP

B&K Precision

DISSOLVED OXYGEN PROBE 760

0

BP 2650

BP 2650

B&K Precision

NI-MH BATTERY PACK

0

LC 2650

LC 2650

B&K Precision

SOFT CARRYING CASE FOR 2650/2658

0

TL 35A

TL 35A

B&K Precision

TEST LEAD 2MM TIP RED & BLACK

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top