Accessories

Image Part Number Description / PDF Quantity Rfq
PA1903

PA1903

Tempo Communications

ADAPTER MOD RJ11 6WAY TIP/RING

2

501R

501R

Tempo Communications

RECEIVER FOR 501

0

501T

501T

Tempo Communications

TRANSMITTER FOR 501

0

IC1

IC1

Tempo Communications

INDUCTIVE COUPLER

0

402T

402T

Tempo Communications

TRANS FOR 402K

0

900B

900B

Tempo Communications

CASE CARRY-HARD 3X HH

1

NC-510

NC-510

Tempo Communications

REMOTE UNIT KIT

1

PA1902

PA1902

Tempo Communications

ADAPTER MOD RJ45 8WAY TIP/RING

13

OM-03

OM-03

Tempo Communications

OMNIMARKER II,GAS (OM-03)

0

402R

402R

Tempo Communications

RECEIVER FOR 402K

0

SM-05

SM-05

Tempo Communications

MARKER SPIKES

0

OM-08

OM-08

Tempo Communications

OMNIMARKER II,WATER (OM-08)

0

20988

20988

Tempo Communications

SOFT CARRY CASE

0

468T-G

468T-G

Tempo Communications

TRANS FOR 468

0

SM-02

SM-02

Tempo Communications

MARKER SPIKES

0

SM-06

SM-06

Tempo Communications

MARKER SPIKES

0

OM-07

OM-07

Tempo Communications

OMNIMARKER II,EUROPOWER (OM-07)

0

468R-G

468R-G

Tempo Communications

RECEIVER FOR 468

0

OM-04

OM-04

Tempo Communications

OMNIMARKER II,FIBER OPTIC (OM-04

0

200C

200C

Tempo Communications

LEATHER CASE FOR 200 SERIES

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top