Accessories

Image Part Number Description / PDF Quantity Rfq
H-PMA

H-PMA

Amprobe

SILICONE HOLSTER

0

UT-300

UT-300

Amprobe

ULTRASONIC TRANSMITTER

0

CC-6010

CC-6010

Amprobe

CARRYING CASE SOFT AT-6010

0

MO-100-LEADS

MO-100-LEADS

Amprobe

SET OF TEST LEADS FOR THE MO-100

9

RS-USB

RS-USB

Amprobe

RS-232 TO USB CONVERTER CABLE

0

FP-6000

FP-6000

Amprobe

TRANSMITTER FUSE FOR AT-6000 SER

0

ADPTR-KIT1

ADPTR-KIT1

Amprobe

LIGHT-CHK ADAPTR KIT US W/ CASE

0

SC-600

SC-600

Amprobe

SIGNAL CLAMP UAT-600 SERIES

0

TL73C

TL73C

Amprobe

GROUND LEAD W/ALLIGATOR CLIP,DM7

0

CC-6000

CC-6000

Amprobe

CARRYING CASE MOLDED AT-6000

0

CC-UAT-600

CC-UAT-600

Amprobe

CARRYING CASE UAT-600 SERIES

0

RS-232 KIT2

RS-232 KIT2

Amprobe

DATA DECRDR F/DMM/CLAMP-ONS

0

BT-5000

BT-5000

Amprobe

RECHARG BATT TRANSMITTER AT-5000

0

CC-ACDC

CC-ACDC

Amprobe

CASE FOR ACDC3000/A1000

0

TP73C

TP73C

Amprobe

PROBE TIP,DM73C

0

MLS55-3

MLS55-3

Amprobe

PIPE TRANSMITTER FOR AT-3500

0

DC205C

DC205C

Amprobe

DELUXE HARD SHELL CASE

0

TL-600-25M

TL-600-25M

Amprobe

25 METER TEST LEAD

0

DM-CT-100

DM-CT-100

Amprobe

CURRENT TRANSDUCER 100A

0

TACH-10-KIT1

TACH-10-KIT1

Amprobe

REFLECTIVE TAPE TIPS FOR TACH-10

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top