Accessories

Image Part Number Description / PDF Quantity Rfq
R8500-RCH

R8500-RCH

REED Instruments

9MM REPLACEMENT CAMERA HEAD

2

R3000SD-PH2

R3000SD-PH2

REED Instruments

GENERAL PURPOSE PH ELECTRODE

23

R2990

R2990

REED Instruments

THERMOCOUPLE ADAPTER

275

R8888-FOAM

R8888-FOAM

REED Instruments

REPLACEMENT FOAM

14

R5600-CLIP

R5600-CLIP

REED Instruments

REPLACEMENT ALLIGATOR CLIP

2

R5900

R5900

REED Instruments

MAGNETIC HANGING STRAP

14

R1007

R1007

REED Instruments

7PH BUFFER POUCHES, 20-PACK

5

R3500-ELECTRODE

R3500-ELECTRODE

REED Instruments

PH ELECTRODE FOR R3500

11

CM-8822NFPROBE

CM-8822NFPROBE

REED Instruments

REPLACEMENT NON-FERROUS PROBE

3

R9050

R9050

REED Instruments

COATING THICKNESS CALIBRATION KI

33

R1430

R1430

REED Instruments

CONDUCTIVITY STANDARD SOLUTION

47

R7900-PROBE

R7900-PROBE

REED Instruments

REPLACEMENT PROBE

7

R9933

R9933

REED Instruments

RH CALIBRATION STANDARD, 33%

15

CA-05A

CA-05A

REED Instruments

MEDIUM SOFT CARRYING CASE

80

R4700SD-PROBE

R4700SD-PROBE

REED Instruments

REPLACEMENT MULTI-FUNCTION PROBE

2

R1420

R1420

REED Instruments

ELECTRODE STORAGE SOLUTION

22

R1400-KIT

R1400-KIT

REED Instruments

4/7/10PH BUFFER SOLUTION KIT

12

R4500SD-PROBE

R4500SD-PROBE

REED Instruments

REPLACEMENT TELESCOPING HOT WIRE

3

R9910SD-CO2

R9910SD-CO2

REED Instruments

REPLACEMENT CARBON DIOXIDE PROBE

4

TM-8811PROBE

TM-8811PROBE

REED Instruments

ULTRASONIC THICKNESS GAUGE PROBE

17

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email