Accessories

Image Part Number Description / PDF Quantity Rfq
6262-02

6262-02

Pomona Electronics

ADAPTER EXTEND FINE PT RED & BLK

67

73040

73040

Pomona Electronics

OSCILLOSCOPE PROBE ACCY KIT

7

1508/POM

1508/POM

Pomona Electronics

HOLDER TEST LEAD WIRES .210" DIA

281

73106-2

73106-2

Pomona Electronics

R/A MAGNET PROBE/RED 6.6MM

38

72904-2

72904-2

Pomona Electronics

CLIP LEAD FOR MICRO GRABBER RED

0

4408/POM

4408/POM

Pomona Electronics

HOLDER TEST LEAD RG59/108 WIRE

323

72904-0

72904-0

Pomona Electronics

CLIP LEAD FOR MICRO GRABBER BLK

0

72905-0

72905-0

Pomona Electronics

CLIP LEAD FOR MICRO GRABBER BLK

6

73106-6

73106-6

Pomona Electronics

R/A MAG PROBE/BLUE 6.6 MM

47

72905-2

72905-2

Pomona Electronics

CLIP LEAD FOR MICRO GRABBER RED

28

73106-0

73106-0

Pomona Electronics

R/A MAGNET PROBE/BLK 6.6MM

42

5955

5955

Pomona Electronics

TRI-FOLD POUCH BLACK

15

4408M

4408M

Pomona Electronics

TOOL HOLDER FOR AIR LEADS

15

6252

6252

Pomona Electronics

COUPLERS TEST LEAD 1RED & 1BLACK

348

6252#

6252#

Pomona Electronics

COUPLER IEC1010 SET PACKAGED

0

5955#

5955#

Pomona Electronics

TRI-FOLD POUCH

0

6146

6146

Pomona Electronics

BAG TEST COMPANION LARGE W/STRAP

0

6553

6553

Pomona Electronics

ADAPTER O-SCOPE TO SMD GRABBER

0

6262-02#

6262-02#

Pomona Electronics

EXTENDED FINE PT TIP ADAP (SET R

0

6443

6443

Pomona Electronics

ADAPTER MICRO OSCILLOSCP TIP SMD

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email