Accessories

Image Part Number Description / PDF Quantity Rfq
05K151-K20S3

05K151-K20S3

Rosenberger

PRECISION N TYPE CALIBRATION ADA

0

CT4140A-2.0A

CT4140A-2.0A

Cal Test Electronics

4MM INLINE FUSE ADAPTER, 1KV CAT

12

PK-ZS-019

PK-ZS-019

Teledyne LeCroy

FREEHAND PROBE HOLDER ZS4000

2

T5-KIT

T5-KIT

Fluke Electronics

KIT STARTER T5 TESTER ACCESSORY

0

UAC-B

UAC-B

AIMtti

UNIVERSAL AC ADAPTOR FOR PSA TF

0

BU-72-2

BU-72-2

Mueller Electric Co.

INSULATOR-ALLIGATOR CLIP PVC RED

248684

409997

409997

FLIR Extech

CARRYING CASE, LARGE VINYL POUCH

0

AP034-DA10

AP034-DA10

Teledyne LeCroy

DIV BY 10 ATTENUATOR PLUG ON A

9

AI-000500-36

AI-000500-36

Mueller Electric Co.

36" GROUND CABLE BU-21CPN

81

03S121-S20S3

03S121-S20S3

Rosenberger

PRECISION 3.5 CALIBRATION ADAPTO

0

02S121-K20S3

02S121-K20S3

Rosenberger

PRECISION 2.92 CALIBRATION ADAPT

0

4112848

4112848

Fluke Electronics

SILVERCAREPLAN-GROUP3-5YR

0

M1047

M1047

Comet America

FU INPUT MODULE FOR LOGGER MS

20

R1430

R1430

REED Instruments

CONDUCTIVITY STANDARD SOLUTION

47

18K12S-000D3

18K12S-000D3

Rosenberger

MINI SMP SHORT

0

CTM-26-2

CTM-26-2

Cal Test Electronics

HEAVY DUTY & AUTOMOTIVE CLIP INS

168

CA899

CA899

FLIR Extech

CASE, VINYL W/SHOULDER STRAP, BE

0

A115

A115

TPI (Test Products International)

THERMOCOUPLE ADAPTER

81

R7900-PROBE

R7900-PROBE

REED Instruments

REPLACEMENT PROBE

7

03K110-K21S3

03K110-K21S3

Rosenberger

PRECISION 3.5 CALIBRATION ADAPTO

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top