Snap Action, Limit Switches

Image Part Number Description / PDF Quantity Rfq
AZC11011Y

AZC11011Y

Panasonic

MAGNELIMIT

0

AH18609-A

AH18609-A

Panasonic

SWITCH SNAP ACTION SPDT 3A 125V

0

AVL3455613-A

AVL3455613-A

Panasonic

SWITCH SNAP ACT SPDT 100MA 125V

0

ABS5512349

ABS5512349

Panasonic

SWITCH SNAP ACT SPDT 100MA 30V

0

ABS1413519

ABS1413519

Panasonic

SWITCH SNAP ACT SPDT 100MA 125V

0

AH15829-A

AH15829-A

Panasonic

SWITCH SNAP ACTION SPDT 1A 125V

0

AZC11911Y

AZC11911Y

Panasonic

MAGNELIMIT

0

AVM3215613

AVM3215613

Panasonic

SWITCH SNAP ACT SPDT 100MA 125V

106

ABV161651

ABV161651

Panasonic

SWITCH SNAP ACTION SPDT 3A 250V

0

ABV1212603

ABV1212603

Panasonic

SWITCH SNAP ACTION SPDT 5A 250V

0

AVL32459-A

AVL32459-A

Panasonic

SWITCH SNAP ACTION SPDT 5A 125V

83

AH1882-A

AH1882-A

Panasonic

SWITCH SNAP ACTION SPDT 1A 125V

0

AH14649-A

AH14649-A

Panasonic

SWITCH SNAP ACTION SPDT 3A 125V

0

AM50626D33-A

AM50626D33-A

Panasonic

SWITCH SNAP ACT SPST-NC 6A 125V

0

ABJ1510609

ABJ1510609

Panasonic

SWITCH SNAP ACTION SPDT 2A 125V

0

ABV1210619

ABV1210619

Panasonic

SWITCH SNAP ACTION SPDT 3A 250V

0

AZC11013Y

AZC11013Y

Panasonic

SWITCH SNAP ACT SPST-NO 5A 125V

0

ABV1215619

ABV1215619

Panasonic

SWITCH SNAP ACTION SPDT 3A 250V

0

ABJ1414419

ABJ1414419

Panasonic

SWITCH SNAP ACT SPDT 100MA 125V

0

AV36049

AV36049

Panasonic

SWITCH SNAP ACTION SPDT 3A 125V

0

Snap Action, Limit Switches

1. Overview

Snap-action switches and limit switches are critical electromechanical components that enable precise control of electrical circuits through mechanical motion. Snap-action switches feature a rapid-acting contact mechanism that ensures quick response to positional changes, while limit switches specifically detect the presence or absence of objects at predefined positions. These devices are fundamental in automation systems, safety circuits, and equipment interlocking, providing reliable feedback for process control and machine protection.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Standard Snap-Action SwitchFast contact actuation, compact size, tactile feedbackAppliances, control panels
Heavy-Duty Limit SwitchMetal housing, high mechanical enduranceIndustrial machinery, conveyor systems
Sealed Snap SwitchIP67-rated enclosure, resistant to dust/moistureOutdoor equipment, washdown environments
Miniature Snap SwitchSub-10mm dimensions, low operating forceMedical devices, IoT sensors

3. Structure and Components

Typical construction includes: - Actuator Mechanism: Lever, plunger, or roller assembly for motion detection - Contact System: Silver alloy contacts with snap-action spring for rapid switching - Housing: Thermoplastic (UL94 V-0) or metal enclosure with mounting features - Terminal Options: Quick-connect terminals, PCB pins, or screw terminals - Environmental Seals: Optional EPDM gaskets or molded-in sealing lips

4. Key Technical Parameters

ParameterTypical RangeImportance
Rated Current0.1-15ADetermines load capacity and contact lifespan
Operating Voltage12-600VAC/DCAffects insulation requirements and arcing resistance
Mechanical Life10 -10 operationsIndicates durability under non-load conditions
Electrical Life10 -10 operationsMeasures contact longevity under rated load
Actuation Force0.5-20NAffects sensitivity and mechanical interface design
Response Time1-10msCritical for high-speed automation applications

5. Application Fields

  • Industrial Automation: CNC machine tool positioning, robotic end-effectors
  • Building Systems: HVAC damper control, automatic door systems
  • Medical Equipment: Diagnostic analyzers, infusion pump occlusion detection
  • Consumer Electronics: Smart home devices, gaming console controllers
  • Transportation: Elevator door safety systems, railcar detection

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Features
OmronD4MC SeriesIP67 rating, 10 mechanical operations
TE ConnectivityMicro Switch TL SeriesUL-certified, 15A rating
ABBPLS SeriesAdjustable actuator, explosion-proof design
OMRONZ-15 Series0.1A low-current switching capability

7. Selection Guidelines

Key considerations include: - Environmental conditions (temperature range, presence of contaminants) - Actuation force requirements vs. mechanical interface limitations - Contact configuration (SPDT/DPDT) and circuit requirements - Certification needs (UL, CSA, CE marks) - Mounting constraints (panel cutout dimensions) Example: For an automatic door system, specify a sealed IP65 switch with 10A/250VAC rating and lever actuator to ensure reliable operation in dusty environments.

8. Industry Trends

Current development directions include: - Integration with IoT systems through embedded sensing and wireless communication - Miniaturization for wearable and portable device applications - Enhanced material science for extended lifespan in harsh environments - Development of hybrid switches combining snap-action with proximity sensing - Increased focus on RoHS-compliant and recyclable materials - Smart diagnostics capabilities with condition monitoring sensors

RFQ BOM Call Skype Email
Top